Download Print this page

Kenmore ULTRASOFT 625.3888 Owner's Manual page 25

Kenmore water system user manual

Advertisement

[i!i !! _; _ !! _; _ !! _; _ !! _;SECTION
5
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
MANUAL
ADVANCE
REGENERATION
CHECK
This check
verifies
proper
operation
of the valve
motor,
brine
tank fill, brine
draw, regeneration
flow
rates,
and other
controller
functions.
Always
make
the initial
checks,
and
the manual
initiated
diag-
nostics.
Note:
The faceplate
display
must
show
normal
op-
erating
screen.
If an error code shows,
first press
the
SELECT
button
to enter
the diagnostic
display.
_
Press
the RECHARGE
button
and hold
in for 3
seconds.
The Recharge
display
shows
as the
softener
enters
the
fill cycle
of regeneration.
When
FILL time begins
to count
down,
remove
the brinewell
cover
and,
using
a flashlight,
ob-
serve
fill water
entering
the tank.
*Note: if the CLEAN
feature
is set to ON, the clean
icon flashes
while
the backwash
or fast rinse
cycles
are in progress,
along
with the minutes
remaining
in each cycle.
This proceeds
the normal
regenera-
tion cycle.
a. If water
does
not enter
the tank,
look for an ob-
structed
nozzle,
venturi,
fill flow plug,
brine tubing,
or brine
valve
riser pipe.
CYCLE FLOW RATES (GALLONS
PER MIN.)
FILL (flow to salt storage tank)
0.3 (1.1 liters)
BRINING
'_
.22 (.83 liters)
BRINE RINSE
l
.15 (.57 liters)
BACKWASH
(flow to drain)
2.0 (7.6 liters)
FAST RINSE
2.0 (7.6 liters)
_
After
observing
fill, press
the RECHARGE
but-
ton
to move
the softener
into brining.
A slow
flow of water
to the drain
will begin.
Verify brine
draw
from
the brine
tank
by shining
a flashlight
into
the brinewell
and
observing
a noticeable
drop
in the liquid
level.
Note:
Be sure a salt bridge
is not preventing
water
with
salt contact.
a. If the softener
does not draw
brine...
...nozzle
and/or
venturi
dirty
or defective.
...nozzle
and venturi
not seated
properly
on gasket.
...restricted
drain
(check
drain
fitting
and hose).
...defective
nozzle
and venturi
seal.
...other
inner
valve
defect
(rotor
seal, rotor
& disc,
wave
washer,
etc.).
Note:
If water
system
pressure
is low, an elevated
drain
hose may cause back pressure,
stopping
brine
draw.
_I_
Again
press
RECHARGE
to move
the softener
into backwash.
Look for a fast flow of water
from
the drain
hose.
a. An obstructed
flow indicates
a plugged
top dis-
tributor,
backwash
flow plug,
or drain
hose.
ImPress
RECHARGE
to move
the softener
into fast
rinse.
Again
look for a fast drain
flow. Allow
the
softener
to rinse
for a few minutes
to flush
out
any brine
that may remain
in the resin
tank from
the brining
cycle test.
_To
return
the
softener
to service,
press
RE-
CHARGE.
[1
BRINE VALVE
, '
FLOAT SETTING
__
float stop
float
FREEBOARD MEASUREMENT
Distance from top of resin tank, to top of resin bed.)
FREEBOARD
7"-11"
resin tank
5-4
Problems,
Questions?
Call 1- 800- 426- 9345 Kenmore
Water Line

Advertisement

loading