[i!i !! :i :_!! :i :_!! :i :_!! :j SECTION
5
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
AUTOMATIC
ELECTRONIC
DIAGNOSTICS
The faceplate
timer
(PWA)
computer
has a self-diag-
nostic
function
for
the
electrical
system,
except
for input
power
and water
meter.
The
computer
monitors
electronic
components
and circuits
for cor-
rect operation.
If a malfunction
occurs,
an error code
appears
in the faceplate
display.
Error #1
Service Required
See Owners
Manual
Diagnostics
The chart
below
shows
the error
codes
that
could
appear,
and the possible
defects
for each code.
While
an error code appears
in the display,
all face
plate buttons
are inoperable
except
the SELECT but-
ton. SELECT remains
operational
so the service
per-
son
can
make
the MANUAL
INITIATED
ELEC-
TRONIC
DIAGNOSTICS
(below)
to further
isolate
the defect,
and check the water
meter.
POSSIBLE DEFECT
MOST LIKELY
_--
_,
LESS LIKELY
CODE
-_
Error #1, Error
motor inoperative / wiring harness or connection to switch / position switch / valve defect causing
#3, Error #4
hiqh torque
Error #5
faceplate timer (PWA)
PROCEDURE
FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug
transformer
from outlet 2. Correct
defect
3. Plug in transformer
4. Wait for 8 minutes.
The error code will return
if the defect was not corrected.
MANUAL
INITIATED
ELECTRONICS
DIAGNOSTICS
_To
enter
diagnostics,
press
the SELECT
button
once to go to the Main Menu.
Move the blackbar
to Service Mode and press Select.
Move black bar
to Diagnostics
and press
Select.
You will see the following
display,
showing
valve
cycle
position,
position
switch
status
(open
or
closed),
and turbine
operation.
valve position indicator
f
{ 10:39:56_M
Pos : SERVICE
0 : 00
Req Pos : SERVICE
Motor : Off
_-_c_
"Kbn: 0_0
Gals: 0
_1_
Days:
_
chgs:
0 _
Last Rch_ : R
/
\
turbine count (no
water
Ilowino_
10:39:56AM
Pos : SERVICE
0 : 00
Req Pos : SERVICE
Motor : Off
_-'_
Trbn : 126
Gals : 0
Days : 1 _Rchgs
: 0
Last Rchg :\4
\
position switch
turbine count (water
indicator (open)
flowin¢l)
TURBINE
OPERATION:
If no
water
is flowing
through
the softener,
the turbine
indicator
displays
3 zeros.
When
water
is flowing,
a 000 to 140 count
repeats
for each gallon
of water passing
through
the
turbine.
To check
for positive
operation
of the tur-
bine
if zeros
are shown,
open
a nearby
soft water
faucet
and observe
the turbine
count.
If you don't
get a reading
in the display,
with faucet
open,
pull
the sensor
from
the valve
outlet
port.
Pass a small
magnet
back and forth
in front
of the
sensor.
You should
get a reading
in the display.
If
you get a reading,
unhook
the in and out plumbing
and check
the turbine
for binding.
switch
sensor
housing
/
turbine
support
& shaft
outlet
POSITION
SWITCH
STATUS:
With the valve in ser-
vice, or any of the recharge
cycles, the switch
indica-
tor will show
open
_N-. While
the valve
is rotating
from
one
position
to another,
the
indicator
will
show
the switch
closed
--,_-. A defect is probable
if
indications
vary
from this pattern.
5-2
Problems,
Questions?
Call 1- 800- 426- 9345 Kenmore
Water Line