Kenmore 625.3835 Use And Care Manual page 21

Kenmore water system user manual
Table of Contents

Advertisement

MANUALLY
INITIATED
ELECTRONIC
DIAGNOSTICS
1. To enter diagnostics,
press the SELECT button
and
hold for three seconds.
The display
will change
to
show turbine
count, valve cycle position,
and position
switch status (open or closed).
Valve Position
Indicator
_4
Im12
Turbine Count
(No Water
Flowing)
uuu!
WATER FLOW
Position Switch
Indicator
(Open)
Turbine Count
(Water
Flowing)
s
Figure 38
Motor
1
Position
Sensor
Switch
j
Housing
I
Turbine
I
Turbine
Support
& Shaft
Valve Outlet
Figure 39
TURBINE
OPERATION:
If no water
is flowing
through
the softener, the turbine
indicator
displays
three zeros.
When water
is flowing,
a 000 to 199 count repeats for
each gallon
of water
passing through
the turbine.
To
check for positive
operation
of the turbine
if zeros are
shown, open a nearby
soft water
faucet
and observe
the turbine
count.
If you don't get a reading
in the dis-
play with faucet open, pull the sensor housing from the
valve outlet
port (see Fig. 39).
Pass a small magnet
back and forth in front of the sensor.
You should get a
reading
in the display.
If you get a reading,
unhook the
inlet and outlet plumbing
and check the turbine
for
binding.
POSITION
SWITCH
STATUS: With
the valve in service,
or any of the recharge cycle positions,
the position
switch indicator will show the switch open.
While
the
valve is rotating from one position
to another,
the posi-
tion switch indicator will show the switch closed.
There
is likely a problem
if indications vary from this pattern.
OTHER INFORMATION:
While
in the diagnostics
screen, the following
information
is available
and may
be beneficial
for various reasons.
This information
is
retained
by the electronic
controller
from the first time
electrical
power is applied
to the unit.
Press and hold the /X UP button
to display
the num-
ber of days this controller
has had electrical
power
applied.
Press and hold the V
DOWN
button
to display
the
number of regenerations
initiated
by this controller
since the model code number was entered.
NOTE: If the electronic
controller
is left in the diagnos-
tic display
(or a flashing
display
when setting
times or hardness), the normal
time of day dis-
play automatically
returns if a button has not
been pressed for 4 minutes.
To return to the
diagnostic
display,
repeat step 1, above.
RESETTING
TO FACTORY
DEFAULTS:
To reset the electronic
controller
to its factory
default
for all settings
(time, hardness, etc.):
1. Press the SELECT button
and hold it until the display
changes
twice to show the flashing
model code.
2. Press the /X UP button to display
a flashing
"SOS".
Figure
40
3. Press the SELECT button,
and the electronic
controller
will restart.
4. Set the present time, hardness, etc., as described
on
pages 12 & 13.
Questions?
Call the I<enmore Water
Line 1-800-426-9345
or visit www.kenmorewater.com