IBM 21Y Maintenance Manual page 145

Type 8657
Table of Contents

Advertisement

Error
Code/Symptom
202-XXX-001
(Failed System
Cache test)
202-XXX-002
(Failed System
Cache test)
206-XXX-000
(Failed Diskette
Drive test)
215-XXX-000
(Failed IDE CD-
ROM test)
217-XXX-000
(Failed BIOS Fixed
Disk test)
Note: If RAID is
configured,
the fixed
disk number
refers to the
RAID logical
array.
217-XXX-001
(Failed BIOS Fixed
Disk test)
Note: If RAID is
configured,
the fixed
disk number
refers to the
RAID logical
array.
217-XXX-002
(Failed BIOS Fixed
Disk test)
Note: If RAID is
configured,
the fixed
disk number
refers to the
RAID logical
array.
136
Netfinity 3500-M20 – Type 8657 Models 21Y, 22Y, 31Y, 32Y,
FRU/Action
1. Microprocessor CPU 1
1. Microprocessor CPU 2
1. Cable
2. Diskette Drive
3. System Board
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
1. Fixed Disk 1
1. Fixed Disk 2
1. Fixed Disk 3

Advertisement

Table of Contents
loading