Duty Cycle - Lincoln Electric Invertec CV500 User Manual

Table of Contents

Advertisement

A - 6
Power Source
Pin
Function
" + " pulse signal for motor control.
1
" + " pulse signal for gas solenoid.
2
" + " control signal for gas purge, cold
3
inch and trigger.
+/- 10V control signal for arc current
4
and arc voltage.
GND for arc current, arc voltage, gas
5
purge, cold inch and trigger control.
GND for gas solenoid and motor
6
control.
Power Source
Pin
Function
A
Output control power +
B
Output control signal
C
Output control power -
D
Output control switch +
E
Output control switch -
F
Ground lead ( case )
SAFETY PRECAUTIONS
Read this entire section of operating
instructions before operating the machine.
WARNING
ELECTRIC SHOCK can kill.
 Do not touch electrically live
parts or electrode with skin or
wet clothing.
 Insulate yourself from work
and ground.
 Always wear dry insulating gloves.
FUMES AND GASES can be
dangerous.
 Keep your head out of fumes.
 Use ventilation or exhaust to
remove fumes from breathing
zone.
WELDING SPARKS can cause
fire or explosion.
 Keep flammable material
away.
 Do not weld on closed
containers.
ARC RAYS can burn eyes and
skin.
 Wear eye, ear and body
protection.
PLEASE SEE ADDITIONAL WARNING
INSTALLATION
TABLE A.2
Lead #
Pin
91
1
92
2
93
3
94
4
95
5
96
6
TABLE A.3
Lead #
Pin
77
A
76
B
75
C
2
D
4
E
G2
F
INFORMATION AT THE FRONT OF THIS
OPERATOR'S MANUAL.

DUTY CYCLE

The duty cycle of a welding machine is the percentage
of time in a 10 minute cycle at which the welder can
operate the machine at rated welding current.
60% duty cycle:
Weld for 6 minutes
Excessive extension of the duty cycle will cause the
thermal protection circuit to activate.
THERMAL PROTECTION
The INVERTEC
protection device. When the machine has gone into
thermal overload, the output will be turned off and the
thermal indicator light will be turned "ON". When the
machine has cooled to a safe temperature, the Thermal
Indicator Light will go out and the machine may resume
normal operation.
Note: For safety reasons the machine's welding output
will not come on after a thermal shutdown until the
output is disabled and re-enabled.
®
INVERTEC
CV/CC500
Wire Feeder
Function
Positive terminal of motor.
Connected to one lead of gas
solenoid.
Control signals output ( gas purge,
cold inch and trigger ).
Control signals output (arc current
and arc voltage ).
Common GND.
Negative terminal of motor; and
connected to another lead of gas
solenoid.
Remote Controller
Function
Pot foot 1
Pot foot 2
Pot foot 3
Switch foot 1
Switch foot 2
Case
Break for 4 minutes
®
machine is equipped with a thermal
A-6
Lead #
91
92
93
94
95
96
Lead #
77
76
75
2
4
G2
Rev. 03