Trane 7½ - 20 Tons Manual page 17

Split system heat pumps
Table of Contents

Advertisement

Performance Data
10 Tons Gross Cooling Capacities and Capacity Curves
Table 8.
Gross Cooling Capacities (MBh) 10 Tons TWA120A Heat Pump Only
Outdoor
Temp (°F)
Head press PSIG
65
Cap. Btuh/1000
Unit kW
Head press PSIG
75
Cap. Btuh/1000
Unit kW
Head press PSIG
85
Cap. Btuh/1000
Unit kW
Head press PSIG
95
Cap. Btuh/1000
Unit kW
Head press PSIG
105
Cap. Btuh/1000
Unit kW
Head press PSIG
115
Cap. Btuh/1000
Unit kW
Notes:
1. Performance data calculated at 15°F subcooling and 20°F superheat and does not include capacity loss due to refrigerant lines.
Figure 9.
Capacity Curves 10 Tons TWA120A Heat Pump Only
SSP-PRC001-EN
Suction Temperature (°F)
30
35
167
172
110.6
121.1
132.1
7.87
8.04
8.22
192
197
105.4
115.4
126.1
8.56
8.75
8.95
219
224
100
109.6
119.9
9.38
9.59
9.82
248
254
94.5
103.7
113.5
10.35
10.58
281
287
88.8
97.6
11.45
11.7
11.96
316
322
83.1
91.4
100.3
12.69
12.95
13.21
40
45
50
178
183
189
143.7
155.9
8.41
8.61
202
208
214
137.3
149.1
9.16
9.38
230
236
243
130.7
142
10.05
10.3
260
267
274
123.8
134.7
10.82
11.07
293
300
307
107
116.8
127.1
12.22
12.48
329
336
343
109.6
119.2
13.48
13.73
55
195
168.6
8.83
221
161.4
9.62
250
153.9
10.55
281
146.1
11.59
315
137.8
12.74
351
129.2
13.98
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5-20 tons

Table of Contents