Table Of Contents; Servicing Notes - Sony MDS-M100 Service Manual

Minidisc deck
Table of Contents

Advertisement

TABLE OF CONTENTS

1.
2.
................................................................... 11
3.
......................................................... 12
4.
.............................................................. 16
5.
6.
6-1. IC Pin Function Description ........................................... 30
6-2. Block Diagram - SERVO Section - ............................... 37
6-3. Block Diagram - MAIN Section - ................................. 39
Schematic Diagrams ....................................................... 42
6-5. Printed Wiring Board - BD Board - ............................. 43
6-6. Schematic Diagram - BD Board (1/2) - ........................ 45
6-7. Schematic Diagram - BD Board (2/2) - ........................ 47
6-8. Schematic Diagram - SW Board - ................................. 49
6-9. Printed Wiring Board - SW Board - .............................. 49
6-11. Printed Wiring Board - MAIN Board - ......................... 55
6-14. Printed Wiring Boards - PANEL/PANEL 2 Boards - ... 61
7.
8.
.................................... 2
............................................... 4
......................... 21
................................................ 66
............................... 70

SERVICING NOTES

SAFETY CHECK-OUT
After correcting the original service problem, perform the follow-
ing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs,
screws, and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The "limit" indica-
tion is 0.75 V, so analog meters must have an accurate low-
voltage scale. The Simpson 250 and Sanwa SH-63Trd are ex-
amples of a passive VOM that is suitable. Nearly all battery
operated digital multimeters that have a 2 V AC range are suit-
able. (See Fig. A)
To Exposed Metal
Parts on Set
0.15 µ F
Fig. A. Using an AC voltmeter to check AC leakage.
MODEL IDENTIFICATION
- BACK PANEL -
MODEL
US model
Canadian model
Singapore model
AEP model
UK model
- 4 -
SECTION 1
1.5 k Ω
Earth Ground
Part No.
Part No.
4-216-840-0π
4-216-840-1π
4-216-840-2π
4-216-840-3π
4-216-840-4π
AC
voltmeter
(0.75 V)

Advertisement

Table of Contents
loading

Table of Contents