Sony MZ-E800 Service Manual page 15

Hide thumbs Also See for MZ-E800:
Table of Contents

Advertisement

• Description of Indication History
History code number
1st
0
1st
1
1st
2
N
0
N
1
N
2
N-1 0
N-1 1
N-1 2
N-2 0
N-2 1
N-2 2
R
• Description of Error Indication Codes
Problem
Indication code
No error
00
01
Servo error
02
03
04
Power error
22
Reset the error display code
After servicing, reset the error display code.
1. Setting the test mode (see page 12).
[DISPLAY]
2. Press the
key activates the self-diagnosis display mode.
3. To reset the error display code, press the
(All the data on the 1st, N, N-1, and N-2 will be reset)
Description
The first error
Displays "00"
Displays "00"
The last error
Displays "00"
Displays "00"
One error before the last.
Displays "00"
Displays "00"
Two errors before the last.
Displays "00"
Displays "00"
Total recording time (Displays "0000" in this set)
Meaning of code
No error
Illegal access target address
was specified
High temperture
Focus error
Spindle error
Low battery
X
key (2 times) when the code is displayed (except "R 0000").
Description
Normal condition
Attempt to access an abnormal address
High temperture
Forcus could not be applied
Abnormal lotation of disc
Momentary interruption detected
– 15 –