• This set provides the Overall adjustment mode that allows CD
and MO discs to be automatically adjusted when in the test mode.
In this overall adjustment mode, the disc is discriminate between
CD and MO, and each adjustment is automatically executed in
order. If a fault is found, the system displays its location. Also,
the manual mode allows each individual adjustment to be auto-
matically adjusted.
• Operation in the test mode is performed with the remote com-
mander. A key having no particular description in the text, indi-
cates a remote commander key.
Setting Method of Test Mode
There are two different methods to set the test mode:
1 Short TAP801 (TEST) on the MAIN board with a solder bridge
(connect pin y; of IC801 to the ground). Then, turn on the
power.
– MAIN Board (Component Side) –
C522
02
R620
8
7
5
148
149
0
6
4
150
151
1
1
152
2
3
140
141
142
136
138
139
134
135
137
2 In the normal mode, turn on the HOLD switch on the set.
While pressing the
key on the set, press the following
x
remote commander keys in the following order:
t
t
N >
N >
t
t
.
N >
.
SECTION 4

TEST MODE

TAP801 (TEST)
R205
1
8
IC802
R1
4
5
X801
58
57
56
54
51
48
44
42
39
36
33
60
59
55
53
50
47
45
41
38
35
32
t
t
.
.
N >
t
t
X
X
Operation in Setting the Test Mode
• When the test mode becomes active, first the display check mode
is selected. (Press the
is not active)
• Other mode can be selected from the display check mode.
• When the test mode is set, the LCD repeats the following dis-
play.
Set LCD display
888
All lit
Remote commander LCD display
All lit
All off
Microcomputer
version
display
• When the
X
time is held so that display can be checked.
Caution: On the set having the microcomputer version 1.000, the
NV reset failure will occur.
Therefore, in executing the NV reset during electrical
adjustment, follow the troubleshooting method of NV
reset to perform the NV reset (see page 17).
Releasing the Test Mode
For test mode set with the method 1:
Turn off the power and open the solder bridge on TAP801 (TEST)
on the MAIN board.
Note: Remove the solders completely. Remaining could be shorted with
the chassis, etc.
For test mode set with the method 2:
Turn off the power.
Note: If electrical adjustment (see page 17) has not been finished com-
pletely, always start in the test mode. (The set cannot start in nor-
mal mode)
t
– 12 –
key once, when the display check mode
x
All off
888
006 V1.000
key is pressed and hold down, the display at that
100
Microcomputer
version display
F1SHUF
u
REC