Connection to the water inlet
,
Water in the machine must not
be used as drinking water.
^ The machine must be connected to
the water supply in accordance with
local and national water authority
regulations.
^ The machine is constructed to
comply with DVGW regulations in
Germany, and may be connected to
a suitable supply without an extra
non-return valve provided that
national regulations allow this.
^ The water pressure (flow rate) must
be a minimum of 0.8 bar (80 kPa).
If the water pressure (flow rate) is
below 2 bar (200 kPa) the fill time is
automatically extended.
The max. permitted static pressure is
6 bar (600 kPa).
If the water pressure is not between
0.8 and 6 bar (80 - 600 kPa), please
contact the Miele Service Department
for advice.
^ The machine is supplied as standard
for connection to a hot water supply
up to a max. temperature of 60 °C.
The inlet hose must be connected to
the hot water stopcock.
If a hot water supply is not available
the inlet hose must be connected to
the cold water stopcock.
^ A stopcock with 3/4 inch male thread
must be provided on site. It should
be easily accessible so that the water
supply can be turned off when the
machine is not in use.
^ The DN 10 inlet hose is approx. 1.7 m
long terminating in a 3/4 inch female
thread.
^ The large surface area filter (supplied
with the machine) must be installed
between the stopcock and the inlet
hose.
,
The water inlet hose must not be
shortened or damaged in any way.
See also the installation diagram
supplied.