Error Messages; Table 2-4 Error Messages - NEC NEAX 2000 IVS Command Manual

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

INFORMATION FOR DATA PROGRAMMING

2.3 Error Messages

When an erroneous operation is performed, or wrong data is entered, an error message is displayed on the
LCD. Error messages and their meanings are shown in
ERROR MESSAGE
DIGIT ERROR
DATA ERROR
CODE NOT USED
DATA NOT FOUND
WAIT BUSY NOW
ASSIGNED ALREADY
HARDWARE ERROR
WRONG
SEE CMxx YYYY
USE CMxxxx
TRK NOT ASSIGNED
xx > xxx: ERROR
CHAPTER 2
Page 10
Revision 2.0

Table 2-4 Error Messages

MEANING OF MESSAGE
Error in the number of digits entered.
The value of the entered data is incorrect.
The command code entered is not in use, or
password is needed.
A Station Number not assigned has been en-
tered.
The station or trunk, for which data is to be
changed, is busy.
This error message is displayed when not
enough digits are entered. For example, when
assigning "12" for a service access code,
even if "123" has already been used for an-
other service access code.
Memory read/write disabled.
• The data stored in the memory is wrong.
• This message is displayed when too many
digits are entered. For example, when as-
signing "123" for a service access code
when "12" has already been used for an-
other service code.
Double assigned error of the same Station
Number or trunk.
The data is already assigned by another com-
mand.
The designated trunk is not assigned.
The first data has been changed by "S" or
"-" button, but the station corresponding to
that first data is not assigned.
ND-45669 (E)
Table
2-4.
Press "ST" or "CE" and enter correct data.
Same as above.
Same as above, or follow the procedure for
entering a password.
Same as above.
Wait until it becomes idle.
Press "ST" or "CE" and enter correct data.
Check switch setting of MP card or replace
MP card with spare.
Clear present data by entering "CCC", or en-
ter correct data.
Station Number intended is already assigned
to First Data of CMxx Confirm.
Command Number and YY Number already
assigned are displayed. Confirm.
Assign the trunk by CM10.
Change the first data by "S" or "-" button, or
reenter the first data by "CE".
ACTION

Advertisement

Table of Contents
loading