Flue System Approvals And Installations

These models have fl ue starting collars on both the top
and the back of the unit. Depending upon the installation,
decide which ONE set of starting collars will be used to at-
tach the fl ue system. The starting collar sealing cap must
remain on the starting collar NOT used.
These models use SLP series direct fl ue components.
Approved fl ue system components are labeled for identi-
fi cation. NO OTHER FLUEING SYSTEMS OR COMPO-
NENTS MAY BE USED. Detailed installation instructions
are included with each fl ue termination kit and should be
used in conjunction with this manual. Figure 7.8 shows
fl ue system components and terminations.
Identifying Flue Components
The fl ue systems installed on this gas fi replace may include
one, two, or three 90° elbow assemblies. The relationships
of vertical rise to horizontal run in fl ue confi gurations using
90° elbows MUST BE strictly adhered to. The rise to run
relationships are shown in the fl ueing drawings and tables
on the next few pages.
WARNING! Risk of Fire! This gas appliance and fl ue as-
Figure 7.8 Flue Components and Terminations
VERTICAL
TERMINATION
HORIZONTAL
TERMINATION
WALL FIRESTOP
90 DEGREE
ELBOW
Flue system termination kits
SLP SERIES
SLP-TRAP2
SLP-TVHW
DVP-FBHT
Heat & Glo • SOHO-B-CEB, SOHO-N-CEB, SOHO-P-CEB • 2111-980 Rev. F • 8/11
FLUE TERMINATION APPROVALS
SLP-TRAP2 HORIZONTAL TERMINATION CAP
SLP-TVHW VERTICAL TERMINATION CAP
DVP-FBHT HORIZONTAL TERMINATION CAP
sembly must fl ue directly to the outside and must never
be attached to a chimney serving a separate solid fuel
burning appliance. Each gas appliance must use a sepa-
rate fl ue system-common fl ue systems are prohibited.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping material could ignite and will in-
terfere with proper operation of doors and louvers.
• Horizontal sections 3 inches (7,62 cm) from the top of
the pipe.
• Horizontal sections 2-1/2 inches (6,35 cm) at wall shield
fi restops.
• Horizontal sections 1 inches (2,54 cm) from sides and
bottom of the pipe.
• Vertical sections 1 inches (2,54 cm) on all sides of pipe.
Failure to keep insulation or other material away from
vent pipe may cause over heating and fi re.
For alternative installations, other than depicted, contact
your dealer for further information.
STORM COLLAR
ROOF FLASHING
HORIZONTAL PIPE
SUPPORT
CEILING
FIRESTOP
PIPE LENGTH
WALL BRACKET