Central Pneumatic 47016 67181 Owner's Manual & Safety Instructions page 13

20 oz. high volume, low pressure gravity feed spray gun
Table of Contents

Advertisement

Delayed or inadequate cleaning will permanently clog the Spray Gun.
Latex paint hardens quickly and permanently inside Spray Gun.
General Troubleshooting Chart
problem
Sputtering Spray
Will Not Spray
Overspray
(Paint drifting to
unintended objects.)
Fluid Tip Leakage
Air Leaking
from Nozzle
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect air supply before service.
Item 47016 67181
NOTICE
Clean the Spray Gun IMMEDIATELY after EVERY use.
possible Causes
1. Low paint level.
2. Cup tipped.
3. Clogged Air Vent.
4. Loose fluid inlet connection.
5. Loose/damaged fluid tip/seat.
1. No pressure at Spray Gun.
2. Fluid Knob not open enough.
3. Fluid too thick.
1. Improper application speed.
2. Improper distance from workpiece.
3. Too much air pressure.
1. Dirty tip.
2. Broken fluid needle spring.
3. Worn or damaged tip.
1. Dirty air valve/seat.
2. Sticking air valve.
3. Damaged air valve spring.
4. Worn/damaged air valve/seat.
5. Bent valve stem.
For technical questions, please call 1-888-866-5797.
Likely Solutions
1. Refill.
2. Hold upright.
3. Clean Air Vent hole.
4. Tighten fluid inlet connection.
5. Adjust or replace fluid tip.
1. Check air hoses.
2. Open Fluid Knob.
3. Thin fluid or increase air pressure.
(Do not exceed maximum.)
1. Move moderately and parallel.
2. Adjust distance.
3. Reduce air pressure.
1. Clean tip.
2. Replace fluid needle spring.
3. Replace tip and/or needle.
1. Clean air valve/seat.
2. Lubricate air valve/seat.
3. Replace air valve spring.
4. Replace air valve.
5. Replace valve stem.
Page 13