4

Electrical Wiring

NOTICE:
The manual override switch, rheostat speed
control and cover plate are supplied. You will need to supply:
14-3 wire with ground; 14-2 wire with ground; standard wall
mount junction box; wire nuts.
• Remove junction box cover plate on the bottom right
side of the fireplace.
• Thread the 14-3 with ground wire through the opening
with the strain relief on the cover plate.
• Match colors to wire harness, (red to red, white to white,
etc.) and secure with wire nuts.
Match colors to wire
harness (red to red,
white to white, etc) and
secure with a wire nut
Figure 4.1
Fan Wiring Diagram
Heat & Glo • NORTHSTAR • 480-2360 Installation Manual • Rev H • 8/20/14
14-3 w/ground
Power to the Fireplace
Snap Disc
bypass switch
NOTICE:
Wiring for fans must be done before framed
enclosure is completed. If using a Heat Zone kit, it also must
be installed before enclosure is complete.
WARNING! Risk of Fire! DO NOT apply combustible fin-
ishing materials over any part of the front of this fireplace.
• The metal fireplace face may only be covered with
noncombustible materials such as ceramic tile, brick,
or stone.
• Do not cover or block any cooling air slots.
Standard wall mount with
Junction Box
14-2 w/ground
WIRE NUT
WHITE
WHITE
GREEN
RED
BLACK
Incoming Power
(110V)