Datalogic PowerScan PD8590-DPM User Manual

Industrial corded handheld bar code reader
Table of Contents

Advertisement

Quick Links

PowerScan™ PD8590-DPM Imager
Industrial Corded Handheld Bar Code Reader
User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic PowerScan PD8590-DPM

  • Page 1 PowerScan™ PD8590-DPM Imager Industrial Corded Handheld Bar Code Reader User’s Manual...
  • Page 2 Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, includ- ing the U.S.A. and the E.U. PowerScan is a registered trademark of Datalogic ADC, Inc. in many countries, including the U.S.A. and the E.U. All other brand and product names may be trademarks of their respec-...
  • Page 3: Table Of Contents

    Introduction Table of Contents Chapter 1 Quick Start Check Required Hardware ..............1-2 USB Interface ..................1-3 RS-232 Interface ..................1-4 Install ESP ....................1-5 Select Model .................... 1-6 Select Protocol and Connect to Imager ........... 1-7 Chapter 2 Using ESP EZ Mode ....................
  • Page 4 Table of Contents Code 128 ....................6-8 Composite ....................6-9 Data Matrix .................... 6-10 GS1 DataBar ..................6-11 Interleaved 2 of 5................... 6-12 MicroPDF417 ..................6-13 PDF417 ....................6-14 Pharmacode ..................6-15 QR Code ....................6-17 UPC/EAN ..................... 6-18 Symbology Identifier ................6-19 Chapter 7 I/O Parameters I/O Parameters by ESP ................
  • Page 5: About This Manual

    Introduction About the POWERSCAN D8590 The key features of the POWERSCAN D8590 are: • Best-in-class DPM decode algorithms • Image Enhance optimization for difficult-to-decode direct part marks • LED targeting pattern • USB and RS-232 interface options • Fast processing •...
  • Page 6: Statement Of Agency Compliance

    Statement of Agency Compliance Statement of Agency Compliance The POWERSCAN D8590 has been tested for compliance with FCC regulations and was found to be compliant with all applicable FCC Rules and Regulations. IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, this device must not be co-located or operate in conjunction with any other antenna or transmitter.
  • Page 7: Quick Start

    1 Quick Start Contents Check Required Hardware ......................1-2 USB Interface ..........................1-3 RS-232 Interface .......................... 1-4 Install ESP ............................ 1-5 Select Model..........................1-6 Select Protocol and Connect to Imager..................1-7 This section is designed to get your POWERSCAN D8590 up and running quickly so you can get a sense of its capabilities and test sample symbols.
  • Page 8: Check Required Hardware

    Check Required Hardware Check Required Hardware Parts List for USB POWERSCAN D8590: • One POWERSCAN D8590 imager • One 12 ft. USB cable (pre-attached to imager) Parts List for RS-232 POWERSCAN D8590: • One POWERSCAN D8590 imager • Cable clip attachment •...
  • Page 9: Usb Interface

    Quick Start USB Interface Note: The USB interface draws its power from the host. USB Configuration Item Description Part Number POWERSCAN D8590 DPM Imager, USB PD8590-DPM USB Cable Included Installation Steps for USB 1. Connect the USB cable to the host. 2.
  • Page 10: Rs-232 Interface

    RS-232 Interface RS-232 Interface Note: Unlike USB, the RS-232 interface does not draw its power from the host computer. RS-232 Configuration Item Description Part Number POWERSCAN D8590 DPM Imager, RS-232 PD8590-DPM Kit, RS-232, 8’ coiled, US power supply CAB-532-KUS Kit, RS-232, 8’ coiled, EU power supply CAB-532-KEU Kit, RS-232, 8’...
  • Page 11: Install Esp

    Quick Start Install ESP Click on the ESP icon to run Datalogic ESP. Note: Datalogic ESP can be installed from the Support Area at www.datalogic.com. ESP System Requirements • 166 MHz Pentium processor (Pentium II processor recommended) • Windows Vista, XP, or 2000 operating system •...
  • Page 12: Select Model

    Select Model Select Model When you start ESP, the following menu will appear: If you need to select another model later, click Switch Model at the top of the screen. 1. Click the POWERSCAN D8590 button and then click OK. If you do not want to make this selection every time you start ESP, uncheck “Show this dialog at startup”.
  • Page 13: Select Protocol And Connect To Imager

    Quick Start Select Protocol and Connect to Imager USB (Standard) • In the Select Protocol dialog box, select the communications protocol you are using and click Next. From the default USB settings, click the Switch Mode button to connect to the reader in USB HID Mode.
  • Page 14 Select Protocol and Connect to Imager RS-232 Option • Select RS-232 and click the Show Connect Symbol button. • Print the RS-232 Connect Mode symbol (also shown in the Install ESP step) and decode it to ensure that you are in the correct communications mode. Keep the printed symbol in a convenient place for future use.
  • Page 15: Using Esp

    2 Using ESP EZ Mode ............................2-2 Application Mode .......................... 2-4 Tree Controls..........................2-5 Menu Toolbar ..........................2-6 Send/Receive ..........................2-16 This section is designed to help you understand the structure and application of ESP. When you open ESP, unless otherwise specified in the ESP Preferences dialog accessible from the Options heading on the menu toolbar, you will enter EZ Mode for initial setup.
  • Page 16: Ez Mode

    EZ Mode EZ Mode The EZ Mode screen is the first thing you will see when you start ESP. EZ Mode will help you get your imager up and running quickly, and will acquaint you with the ESP interface. The purpose of Dot Peen Enhanced in Illumination Quick Setup is to optimize settings for typical dot peen marks.
  • Page 17: Image Quality

    Using ESP Image Quality The video view in EZ Mode (and also on the Video tab in I/O Parameters) allows you to capture images from the imager for further analysis. If Upload Images is checked and you click the Start button, image captures will be uploaded automatically for every good read. Images will also be uploaded for every no read, upon release of the imager’s trigger.
  • Page 18: Application Mode

    Application Mode Application Mode Application Mode gives you access to a robust configuration environment, including tree controls that let you make precise changes to operation parameters, and graphic interfaces that make configuring your imager easy and intuitive. Click here to Click on this icon to return to return to this view from...
  • Page 19: Tree Controls

    Using ESP Tree Controls To make changes to configuration settings in the tree controls: 1. Left click on the to expand or collapse the tree. 2. Double click on the parameter and click once in the selection box to view options. 3.
  • Page 20: Menu Toolbar

    Menu Toolbar Menu Toolbar File > New Whenever New is selected from the File menu, the default configuration of ESP is loaded. Open / Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open.
  • Page 21 Using ESP Model The Model menu allows you to select between reader models. When you choose another model, the current connection with your present model will be terminated. New Model To connect to another model, select New Model, choose the model you want, and click OK. All models you have selected and enabled will continue to appear in the dropdown model menu.
  • Page 22 Menu Toolbar Options You can use the Options menu to save memos and set up ESP preferences. Preferences will be saved and loaded into ESP the next time ESP is opened, whether or not you save the ESP file to the host computer. Preferences >...
  • Page 23 Using ESP Terminal Tab When Show Non-Printable Characters is checked, characters such as ‘CRLF’ will be displayed in the terminal window. When the Enhanced Format radio button is checked, subscript and superscript formatting is shown. When Display incoming data even when not in focus is checked, data from the imager will continue to appear in the terminal even when...
  • Page 24 Menu Toolbar Bar Code Options Tab Sizing Information Sets Bar Width (in mils) of symbols that can be created in ESP. 2-10 POWERSCAN D8590 User’s Manual...
  • Page 25: Advanced Tab

    Using ESP Advanced Tab The Auto Sync dialog on the Advanced tab allows you to determine whether Auto Sync will be automatically enabled in sections of ESP where it is used, or if it will ask you before it enables Auto Sync functions. Always Ask Before Auto Sync Occurs If you check this option box, you are then able to determine what specific Auto Sync functions will be enabled.
  • Page 26 Menu Toolbar Preferences > Advanced Tab (cont.) Ask to Save ESP File when Quitting When enabled, prompts the user to save a .esp file when ending a session. The .esp file will be saved in the location specified by the user. Connect to Readers via TCP/IP When enabled, shows the TCP/IP Connection Wizard by default.
  • Page 27 Using ESP Document Memo The information you type in the Document Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Document Memo item on the Options menu. Model Memo Similar to Document Memo, the information you type in the Model Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Model Memo item on the Options menu.
  • Page 28 Menu Toolbar Connection Wizard When you choose to connect to the imager via the Connection Wizard, you will first need to select the correct protocol (see Select Protocol and Connect to Imager). When you have successfully connected to the imager you will see one of the two following displays in the status bar at the lower right of the screen: RS-232: USB:...
  • Page 29 Using ESP View The options in the View menu correspond to icons on the operations toolbar (Parameters, Setup, Terminal, Utilities). Each option allows you to configure the imager or to perform various other functions in the chosen view. The View menu also allows you to access the Bar Code Dialog. Bar Code Dialog In the Bar Code Dialog you can directly type the text and commands you want to encode.
  • Page 30: Send/Receive

    Send/Receive Send/Receive To access Receive, Save, Default, and Advanced options, click the Send/Recv button. You can also access these options by right-clicking in any of the configuration views. Receive Reader Settings From the Send/Recv menu, select Receive Reader Settings. This option is useful if you want to receive the imager’s settings and save them as a file for later retrieval.
  • Page 31 Using ESP Default When you select Default Current Menu Settings or Default all ESP Settings you are only defaulting settings in ESP. The imager is not affected unless you download new settings. Advanced Options Send Current View This is the same as Save to Reader >...
  • Page 32 Send/Receive NOTES 2-18 POWERSCAN D8590 User’s Manual...
  • Page 33: Basic Operations

    3 Basic Operations Contents Targeting and Decoding ....................... 3-2 Scanning Guidelines........................3-3 Decode Zones and Lighting Zones....................3-4 Illumination System ........................3-7 Illumination Sequence ........................3-9 This section explains how to practice targeting and triggering, and how to begin configuring the imager.
  • Page 34: Targeting And Decoding

    Targeting and Decoding Targeting and Decoding The POWERSCAN D8590 features simple blue targeting LEDs to indicate optimal read range. 1. Hold the imager about 6” from the mark and align the blue targeting pattern as shown below. 2. Move the front of the imager steadily downward toward the mark and parallel to the mark surface.
  • Page 35: Scanning Guidelines

    Basic Operations Scanning Guidelines The POWERSCAN D8590 makes reading the most difficult direct part marks easy. The following guidelines will help ensure optimal performance: • In the default illumination setup, allow the POWERSCAN D8590 to run through its illumination sequences before terminating the read cycle. The POWERSCAN D8590 captures several images with each illumination zone, evaluating the optimum settings.
  • Page 36: Decode Zones And Lighting Zones

    Decode Zones and Lighting Zones Decode Zones and Lighting Zones The following chart provides a guideline for overall read performance based on mark size. Actual range for direct part marks will vary based on mark parameters and the illumination zone required for readings. The chart below is intended as a guideline. Decode Zones POWERSCAN D8590 User’s Manual...
  • Page 37 Basic Operations Lighting Zones The following charts indicate the POWERSCAN D8590’s illumination zones. Dome Lighting Zone Dome illumination de-emphasizes surface texture and elevation (curved surface). Dome Illumination Texture and Elevation are De-Emphasized on the Mark’s Surface POWERSCAN D8590 User’s Manual...
  • Page 38 Decode Zones and Lighting Zones Low Angle Lighting Zone Low Angle illumination emphasizes surfaces texture and elevation (curved surface). Low-Angle Illumination Texture and Elevation are Emphasized on the Mark’s Surface POWERSCAN D8590 User’s Manual...
  • Page 39: Illumination System

    Basic Operations Illumination System The POWERSCAN D8590 ensures reliable decoding of the toughest direct part marks. Through an advanced combination of low angle (dark field) and multi-colored dome (bright field) illumination techniques, the imager provides even illumination of flat, shiny surfaces, enhancing embossed features, or differentiating features on curved surfaces.
  • Page 40 Illumination System Dome Illumination Dome illumination provides diffused, uniform light. The large, solid angle of illumination supports imaging of shiny flat surfaces or curved surfaces. This zone is useful on specular and non-specular surfaces, ideal for de-emphasizing surface texture and elevation (curves).
  • Page 41: Illumination Sequence

    Basic Operations Illumination Sequence The POWERSCAN D8590 is configured to provide the broadest reading capabilities “out of the box”. Just point and shoot to read most marks. This is achieved by combining the illumination system with advanced decode algorithms. The POWERSCAN D8590 automatically cycles through a default combination of the illumination zones each time the user pulls the trigger to decode a mark.
  • Page 42 Illumination Sequence NOTES 3-10 POWERSCAN D8590 User’s Manual...
  • Page 43 4 Communications Contents Communications by ESP......................4-2 Communications Overview......................4-3 USB Interface ..........................4-4 RS-232 Interface .......................... 4-5 Preamble ............................4-7 Postamble............................. 4-9 Preamble and Postamble by ESP ....................4-11 Keyboard Mapping ........................4-12 Text Commands ......................... 4-13 Other Communications Settings in ESP..................4-14 This section includes connection parameters and options for communicating with the POWERSCAN D8590 in various interfaces.
  • Page 44: Communications By Esp

    Communications by ESP Communications by ESP To make changes to configuration settings in the Communications tree control: 1. Left click on the + to expand the tree. 2. Double click on the parameter and click once in the selection box to view options.
  • Page 45: Communications Overview

    Communications Communications Overview All POWERSCAN D8590 imagers are shipped with a USB cable. You can also add RS-232 capabilities and configure your imager accordingly. Whenever you default the imager, it will return to the default settings of whichever interface you are using. Defaulting the imager does not remove preamble and postamble formatting.
  • Page 46: Usb Interface

    USB Interface USB Interface USB Keyboard is the default interface in which data is transferred to a Windows-based text program as keyboard data. USB Interface for detailed steps on setting up the USB Interface. USB Keyboard Mode Data is entered as keyboard sequences. You need to read this symbol whenever you are changing from a different interface to USB.
  • Page 47: Rs-232 Interface

    Communications RS-232 Interface Enabling either of these modes will disable USB communications and require you to default the imager or read the “USB Keyboard” symbol to return to USB. RS-232 Interface for detailed steps on setting up the RS-232 Interface. RS-232 Default Settings This mode is the standard way of transferring unformatted, unpacketized data through the RS-232 port.
  • Page 48 RS-232 Interface Parity (RS-232) Parity is an error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd. It only needs to be changed if necessary to match the host setting.
  • Page 49: Preamble

    Communications Preamble A preamble is a character or series of characters that is added to the beginning of a decoded data string. Preamble characters will appear in the order that they are enabled (left to right). For example, if you enable a comma and then a space, and then decode a symbol containing the data ‘ABC’, your output will look like this: The only limit to the number of preambles enabled is the total memory size available.
  • Page 50 Preamble USB or PS/2 Keyboard Preamble Comma Space Note: To erase all preamble Erase Preamble and postamble and Postamble data, read the Data symbol at right: Erase All Preamble Data POWERSCAN D8590 User’s Manual...
  • Page 51: Postamble

    Communications Postamble A postamble is a character or series of characters that is added to the end of a decoded data string. Postamble characters will appear in the order that they are enabled (left to right). For example, if you enable a space and then a comma, and then decode a symbol containing the data ‘ABC’, your output will look like this: The only limit to the number of postambles enabled is the total memory size available.
  • Page 52 Postamble USB or PS/2 Keyboard Postamble Comma Space Enter Erase All Postamble Data Note: To erase all postamble Erase Preamble and preamble and Postamble data, read the Data symbol at right: 4-10 POWERSCAN D8590 User’s Manual...
  • Page 53: Preamble And Postamble By Esp

    Communications Preamble and Postamble by ESP Characters can also be added to the beginning and end of data strings using ESP. There are a few different ways to do this, using the interface shown below. You will see the Communications tree control on the left, and the Preamble/Postamble interface on the right.
  • Page 54: Keyboard Mapping

    Keyboard Mapping Keyboard Mapping The Keyboard Mapping feature provides alternatives for keyboards that do not conform to US English mapping. Note: Universal Keyboard mapping is slightly slower than the other language-specific options, because it maps data by reference to the full set of ASCII characters. The advantage of Universal Keyboard mapping is that it allows any language and keyboard layout to be mapped.
  • Page 55: Text Commands

    Communications Text Commands When the Text Commands feature is enabled, the POWERSCAN D8590 can accept text commands via RS-232 connections and USB Virtual COM modes. Note: Text Commands are not supported in USB HID Mode. Enable Text Disable Text Save Commands Commands Settings...
  • Page 56: Other Communications Settings In Esp

    Other Communications Settings in ESP Other Communications Settings in ESP Some ESP Communications options are unique to the software, and do not have corresponding programming symbols. These options are explained below. Reader Packet Format Data that is sent from the imager to the host in Raw format is sent without packet framing or check characters.
  • Page 57: Usb Keyboard Rate

    Communications USB Keyboard Rate Requests that the host polls the USB POWERSCAN D8590 at the rate specified (1 to 255 ms). Keyboard Inter Message Delay Places a delay between each character that is output by the imager when in Keyboard Mode.
  • Page 58 Other Communications Settings in ESP NOTES 4-16 POWERSCAN D8590 User’s Manual...
  • Page 59: Read Cycle

    5 Read Cycle Contents Read Cycle by ESP........................5-2 Button Stay-Down Time ........................5-3 Ignore Duplicate Symbol Timeout ....................5-4 Region of Interest..........................5-5 This section contains information on how to set your imager to the most efficient and effective parameters for your application. POWERSCAN D8590 User’s Manual...
  • Page 60: Read Cycle By Esp

    Read Cycle by ESP Read Cycle by ESP To make changes to configuration settings in the Read Cycle tree control: 1. Left click on the to expand the tree. 2. Double click on the parameter 4. Left click again on the and click once in the selection box open screen to complete to view options.
  • Page 61: Button Stay-Down Time

    Read Cycle Button Stay-Down Time Button Stay-Down Time sets the amount of time (in seconds) that the imager will continue to process the current “decode symbol” event. The imager will behave as if the trigger is being activated for this specified amount of time. POWERSCAN D8590 User’s Manual...
  • Page 62: Ignore Duplicate Symbol Timeout

    Ignore Duplicate Symbol Timeout Ignore Duplicate Symbol Timeout Ignore Duplicate Symbol Timeout sets the imager not to output the same symbol data multiple times within the time period designated. POWERSCAN D8590 User’s Manual...
  • Page 63: Region Of Interest

    Read Cycle Region of Interest Region of Interest allows the user to determine the size of the image window to be captured and decoded. Note: Using a smaller Region of Interest, if possible, may enhance read cycle performance. Full Image (1280 x 1024) (Default) Partial Image (800 x 600) Save Settings Region of Interest by ESP...
  • Page 64 Region of Interest NOTES POWERSCAN D8590 User’s Manual...
  • Page 65 6 Symbologies Contents Symbologies by ESP ........................6-2 Aztec............................. 6-3 BC412............................6-4 Codabar............................6-5 Code 39 ............................6-6 Code 93 ............................6-7 Code 128 ............................6-8 Composite ............................ 6-9 Data Matrix ..........................6-10 GS1 DataBar ..........................6-11 Interleaved 2 of 5........................6-12 MicroPDF417..........................
  • Page 66: Symbologies By Esp

    Symbologies by ESP Symbologies by ESP To make changes to configuration settings in the Symbologies tree control: 1. Left click on the to expand the tree. 2. Double click on the parameter and click once in the selection box to view options. 3.
  • Page 67: Aztec

    Symbologies Aztec Read the following symbols to enable/disable Aztec settings: Aztec On Aztec Off (Default) Save Settings Aztec by ESP Sample Aztec Symbol POWERSCAN D8590 User’s Manual...
  • Page 68: Bc412

    BC412 BC412 Read the following symbols to configure BC412 settings: BC412 Off (Default) BC412 On BC412 On, Remove Check Digit Save Settings BC412 by ESP Sample BC412 Symbol POWERSCAN D8590 User’s Manual...
  • Page 69: Codabar

    Symbologies Codabar Read the following symbols to enable/disable Codabar settings: Codabar On (Default) Codabar Off Save Settings Codabar by ESP ESP allows you to enable a checksum, or to enable a checksum and remove it from the decode result. Sample Codabar Symbol POWERSCAN D8590 User’s Manual...
  • Page 70: Code 39

    Code 39 Code 39 Read the following symbols to configure Code 39 settings: Code 39 On (Default) Code 39 Off Enable Checksum Disable Checksum (Default) Enable Checksum and Strip from Result Code 39 Extended Code 39 Extended Full ASCII On Full ASCII Off (Default) Save Settings Code 39 by ESP...
  • Page 71: Code 93

    Symbologies Code 93 Read the following symbols to enable/disable Code 93 settings: Code 93 On (Default) Code 93 Off Save Settings Code 93 by ESP Sample Code 93 Symbol POWERSCAN D8590 User’s Manual...
  • Page 72: Code 128

    Code 128 Code 128 Read the following symbols to enable/disable Code 128 settings: Code 128 On (Default) Code 128 Off Save Settings Code 128 by ESP Sample Code 128 Symbol POWERSCAN D8590 User’s Manual...
  • Page 73: Composite

    Symbologies Composite Composite consists of a 1D component associated with an adjacent 2D component. A successful decode is required for both the 1D and 2D components before the POWERSCAN D8590 outputs a result. When Composite is enabled, the unit decodes the 1D component first. Important: EAN-8, EAN-13, UPC-A, and UPC-E cannot be decoded individually when Composite is enabled.
  • Page 74: Data Matrix

    Data Matrix Data Matrix Read the following symbols to enable/disable Data Matrix settings: Data Matrix ECC 0-140 On (Default) Data Matrix ECC 0-140 Off Save Settings Data Matrix by ESP Sample Data Matrix Symbol 6-10 POWERSCAN D8590 User’s Manual...
  • Page 75: Gs1 Databar

    Symbologies GS1 DataBar Read the following symbols to configure GS1 DataBar settings: All DataBar On (Default) All DataBar Off DataBar Limited On DataBar-14 and DataBar-14 Stacked On DataBar Expanded On Save Settings GS1 DataBar by ESP Sample DataBar-14 Limited Symbol Sample DataBar-14 Stacked Symbol Sample DataBar Expanded Symbol Sample DataBar-14 Symbol...
  • Page 76: Interleaved 2 Of 5

    Interleaved 2 of 5 Interleaved 2 of 5 Read the following symbols to configure Interleaved 2 of 5 settings: Interleaved 2 of 5 On (Default) Interleaved 2 of 5 Off Interleaved 2 of 5 Two Digits On Interleaved 2 of 5 Two Digits Off Interleaved 2 of 5 Four Digits On Interleaved 2 of 5 Four Digits Off Interleaved 2 of 5 Checksum On...
  • Page 77: Micropdf417

    Symbologies MicroPDF417 Read the following symbols to enable/disable MicroPDF417 settings: MicroPDF417 On MicroPDF417 Off (Default) Save Settings MicroPDF417 by ESP 6-13 POWERSCAN D8590 User’s Manual...
  • Page 78: Pdf417

    PDF417 PDF417 Read the following symbols to enable/disable PDF417 settings: PDF417 On (Default) PDF417 Off Save Settings PDF417 by ESP Sample PDF417 Symbol 6-14 POWERSCAN D8590 User’s Manual...
  • Page 79: Pharmacode

    Symbologies Pharmacode Read the following symbols to enable/disable Pharmacode settings: Pharmacode Off (Default) Pharmacode On Save Settings Pharmacode by ESP Fixed Symbol Length Status When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. Symbol Length Specifies the exact number of bars that must be present for the imager to recognize and decode the Pharmacode symbol.
  • Page 80 Pharmacode Direction Specifies the direction in which a symbol can be read. Fixed Threshold Value Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar. Sample Pharmacode Symbol 6-16 POWERSCAN D8590 User’s Manual...
  • Page 81: Qr Code

    Symbologies QR Code Read the following symbols to configure QR Code settings: QR Code On QR Code and Micro QR Code Off Micro QR On QR Code and Micro QR Code On (Default) Save Settings QR Code by ESP Sample QR Code Symbol Sample Micro QR Code Symbol 6-17 POWERSCAN D8590 User’s Manual...
  • Page 82: Upc/Ean

    UPC/EAN UPC/EAN Read the following symbols to configure UPC/EAN settings: UPC On (Default) UPC Off UPC Expansion On (Default) UPC Expansion Off EAN On (Default) EAN Off Save Settings UPC/EAN by ESP Sample UPC-E Symbol Sample UPC-A Symbol 6-18 POWERSCAN D8590 User’s Manual...
  • Page 83: Symbology Identifier

    Symbologies Symbology Identifier When Symbology Identifier is enabled, an AIM (Association for Automatic Identification and Mobility) preamble is added to decoded data output (see the AIM Symbology Identifiers list). This preamble identifies what kind of symbology has been decoded. Symbology Identifier On Symbology Identifier Off (Default) Save Settings Symbology Identifier by ESP...
  • Page 84 Symbology Identifier NOTES 6-20 POWERSCAN D8590 User’s Manual...
  • Page 85: I/O Parameters

    7 I/O Parameters Contents I/O Parameters by ESP.........................7-2 Operational Feedback........................7-3 Gain Control ..........................7-4 Exposure ............................7-5 Data Validation..........................7-6 This section contains information on how to set your imager to the most efficient and effective parameters for your application. POWERSCAN D8590 User’s Manual...
  • Page 86: I/O Parameters By Esp

    I/O Parameters by ESP I/O Parameters by ESP To make changes to configuration settings in the I/O Parameters tree control: 1. Left click on the to expand the tree. 2. Double click on the parameter 4. Left click again on the and click once in the selection box open screen to complete to view options.
  • Page 87: Operational Feedback

    I/O Parameters Operational Feedback Sound/Vibration Condition Sequence: AMBER Successful Power-On 1 Beep / Vibration GREEN AMBER Successful Connection with Host via USB 1 Beep / Vibration None Successful Decode and Data Transfer to Host 1 Beep / Vibration Flash GREEN 2 Beeps / Vibrations Configuration Symbol Successfully Decoded separated by short...
  • Page 88: Gain Control

    Gain Control Gain Control Gain Control is a system that controls gain in the captured image—how bright or dark the resulting image will be. The higher the gain, the brighter the image. When the POWERSCAN D8590 is set to Adaptive mode, it will automatically maintain the proper setting for gain based on the captured image in order to produce the best setting to perform a decode.
  • Page 89: Exposure

    I/O Parameters Exposure The larger the Exposure value, the longer the pixels in the candidate image are exposed, allowing the imager to collect more light. Note: A larger exposure value may cause blurred images. POWERSCAN D8590 User’s Manual...
  • Page 90: Data Validation

    Data Validation Data Validation Data Validation is used to confirm that a decoded string from the imager has complied with a particular company, industry, or ISO standard. POWERSCAN D8590 Data Validation is compliant with Department of Defense Unique Identification and ISO/IEC 15434 (Information Technology –...
  • Page 91 UII Enabled with Error Messages UII:UN123456789ABCDEFG;Construct_1;25SUN123456789ABCDEFG;;;;;; CPN:87654321;PNR;PNR 87654321;;;;;; LBN:87654321;30T;30T87654321;;;;;; UII:12345678 CPN:87654321;Construct_1_2/PNR;UID 12345678;PNR 87654321;;;;; UII:12345678 LBN:87654321;Construct_1/30T;25S12345678;30T87654321;;;;; (15434 ERROR: HEADER - 1ST POSITION);Datalogic Data Validation Disabled The imager will return to normal output behavior without performing data validation. POWERSCAN D8590 User’s Manual...
  • Page 92 Data Validation ISO/IEC 15434 ISO/IEC 15434 specifies a transfer structure, syntax, and coding of messages and data formats when using high capacity automatic data capture (ADC) technologies. The following ISO/IEC 15434 data output options are applicable to Data Matrix ECC 200 symbols only and have no effect on other symbologies.
  • Page 93 I/O Parameters Data Validation Settings The following symbols control Data Validation functions: UII Enabled Enabled with Pass Through UII Enabled with ISO/IEC 15434 Error Messages Enabled Data Validation ISO/IEC 15434 Enabled Disabled (Default) with Error Messages Save Settings Data Validation by ESP Each of the Data Validation Settings can also be enabled in ESP’s I/O Parameters tree control.
  • Page 94 Data Validation Detailed Output Format The table below describes data validation output in detail. Note: UII Enabled with Pass Through will add the prefix DATA to non-UII output for all symbologies. Note: UII Enabled with Error Messages will output the following format: UII/CPN/LBN; DF0;...
  • Page 95 I/O Parameters UII Enabled with Error Messages Content of Decoded Data UII/CPN/LBN Matrix Symbol UII:UII_data Constructed UII type Valid UII Example: UII:12345678 Example: Contruct_1 CPN:CPN_data Constructed CPN type Valid CPN Example: CPN:87654321 Example: PNR Valid LBN LBN:LBN_data Constructed LBN type Example: LBN:87654321 Example: 30T UII:UII_data CPN:CPN_data...
  • Page 96: Error Messages

    Data Validation Error Messages The following is a list of potential error messages. 15434 ERROR: DATA ELEMENT SEPARATOR 15434 ERROR: DOUBLE TRAILER 15434 ERROR: FORMAT INDICATOR 15434 ERROR: HEADER - 1ST POSITION 15434 ERROR: HEADER - 2ND POSITION 15434 ERROR: HEADER - 3RD POSITION 15434 ERROR: HEADER - 4TH POSITION 15434 ERROR: HEADER - GROUP SEPARATOR 15434 ERROR: TRAILER - END OF TRANSMISSION...
  • Page 97 8 Advanced Operations Contents Dot Peen Enhanced Illumination Settings ..................8-2 Illumination Settings by ESP ......................8-3 Lock Settings ..........................8-6 This section introduces several settings that can be applied to speed up processing or improve readability in various circumstances. POWERSCAN D8590 User’s Manual...
  • Page 98: Dot Peen Enhanced Illumination Settings

    Dot Peen Enhanced Illumination Settings Dot Peen Enhanced Illumination Settings The POWERSCAN D8590’s Dot Peen Enhanced illumination settings can be controlled using the configuration symbols shown here. They can also be controlled in ESP’s Mode. Note: The illumination default mode will reset the imager’s illumination settings to factory default.
  • Page 99: Illumination Settings By Esp

    Advanced Operations Illumination Settings by ESP The POWERSCAN D8590’s illumination settings can also be controlled using the graphic interface on the Illumination tab in ESP’s I/O Parameters view. Define how many illumination Click this button to default Click Create Bar Code to steps (1 - 8) the imager will cycle settings for the imager’s encode illumination settings...
  • Page 100 Illumination Settings by ESP Image Enhance Settings Image Enhance settings apply morphological pre-processing (erosion and dilation) to symbol cells to improve readability. Symbols that are under-marked or over-marked can benefit from Image Enhance settings. The Grow Dark and Grow Light checkboxes allow you to determine which cells will be enhanced (grown).
  • Page 101 Advanced Operations Low Resolution Image Low Resolution Image reduces the number of pixels in the image by 50%, which is helpful when the symbol to be decoded has a large number of pixels per element (e.g. a large Data Matrix with a 100 mil cell size, or a 1D symbol with large bar widths). This feature improves processing speed, because the image sizes are smaller.
  • Page 102: Lock Settings

    Lock Settings Lock Settings Read the symbols below to lock or unlock imager settings. Note: This feature does not lock preamble and postamble programming symbols, Clear XML Rules, or postamble erase/none commands. Lock Imager Unlock Imager Settings Settings Save Settings POWERSCAN D8590 User’s Manual...
  • Page 103 9 Terminal Contents Terminal View..........................9-2 Find ...............................9-3 Send ..............................9-4 Macros............................9-5 Terminal Right-Click Menu ......................9-6 Terminal Dropdown Menu ......................9-7 This section describes the Terminal interface and macro functions in ESP. POWERSCAN D8590 User’s Manual...
  • Page 104: Terminal View

    Terminal View Terminal View Click the Terminal button. You will see the following view: Terminal Clear screen, copy, Type text Type text here to screen paste, save. commands find matching text in here. the terminal window. Macros listed Click on desired Click on Macros arrow to Add Macro, on this bar.
  • Page 105: Find

    Terminal Find The Find function allows you to enter text strings to be searched for in the terminal window. For example, suppose a series of symbols have been scanned into the terminal view and you want to determine if a particular symbol whose data begins with “ABC” has been read. 1.
  • Page 106: Send

    Send Send The Send function allows you to enter text commands and then send them to the imager. (See Text Commands.) For example, suppose you want to disable the vibrate function in the imager. To disable vibrate using a text command, you would enter “P%A10” (the command that disables vibrate) in the text field and click Send.
  • Page 107: Macros

    Terminal Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name. When you click Move to Start, the names of all the macros appear, as shown at left. Choose which macro button you want to appear in the first position at the bottom of the terminal view.
  • Page 108: Terminal Right-Click Menu

    Terminal Right-Click Menu Terminal Right-Click Menu Right click in the terminal window to display the following menu: • Copy selected text to clipboard. • Paste from terminal or other text. • Clear all text in terminal window. • Select All text in the terminal window. •...
  • Page 109: Terminal Dropdown Menu

    Terminal Terminal Dropdown Menu The terminal dropdown menu allows you to capture and save current text, and it also includes the functions defined for the Terminal Right-Click Menu. • Capture Text... lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened.
  • Page 110 Terminal Dropdown Menu NOTES POWERSCAN D8590 User’s Manual...
  • Page 111 10 Utilities Contents Device Control..........................10-2 Differences from Default ......................10-3 Firmware .............................10-4 Advanced ............................10-6 This section explains ESP’s Utilities features. These include Device Control, an interface that lets you perform major operations with one click; Differences from Default, which shows all currently enabled POWERSCAN D8590 settings that are not default settings; Firmware, where you can update your imager’s firmware;...
  • Page 112: Device Control

    Device Control Device Control This feature allows you to clear data stored in the imager’s memory, to default the imager, to deactivate or clear XML rules, to upload or delete stored errors, to reboot the imager, and to delete stored results. •...
  • Page 113: Differences From Default

    Utilities Differences from Default Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different from default will appear in the left column (shown below), and descriptions of those settings will appear in the right column.
  • Page 114: Firmware

    Firmware Firmware The Firmware view in ESP Utilities is a simple way to update and verify your imager’s firmware and to update batch files. Choose App Code from the Firmware Update dropdown menu and click Start to install new firmware in the imager. Use this dropdown menu to The Firmware Verification tool locate batch files in the host...
  • Page 115 Utilities Imager ID Another way to query the imager for its identifying information is by reading the following symbol: Imager ID Save Settings The host’s text program will output a data string containing the imager’s identifying information in the following format: Serial number Hardware version Build number...
  • Page 116: Advanced

    Advanced Advanced The Advanced tab in Utilities features an archive of all batch files containing imager configuration commands. Each batch file’s extension is .crb, and each file contains the fundamental code for programming the imager. Notice that the names of the batch files correspond with the numbers beneath all the Data Matrix configuration symbols.
  • Page 117 Appendices Appendix A General Specifications ....................A-2 Appendix B Electrical Specifications .................... A-4 Appendix C Default/Reset Procedure................... A-7 Appendix D Maintenance ......................A-8 Appendix E Troubleshooting ......................A-9 POWERSCAN D8590 User’s Manual...
  • Page 118: Appendix A General Specifications

    General Specifications Appendix A — General Specifications Mechanical Note: Nominal Height: 7” (180 mm) dimensions Width: 2.5” (63 mm) shown. Typical Depth: 4.5” (114 mm) tolerances apply. Weight: 7.2 oz. (204 g) (not including cable) Detail A Environmental Operating temperature: 0° to 50° C (32°...
  • Page 119 Safety Certifications FCC, CE, RoHS/WEEE Copyright ©2013 Datalogic S.p.A. All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes.
  • Page 120 Electrical Specifications Appendix B — Electrical Specifications Power Requirements: 5 VDC (mA) Typical: 408mA; Peak: 500mA, Idle: 285mA PIN 1 VIN- Input Voltage to the voltage regulators/battery charging IC PIN 2 RS-232_TX - RS-232 level serial transmit signal PIN 3 RS-232_RX - RS-232 level serial receive signal PS/2_DATA_UART_RX_USB_DP - PS/2 clk to host/ UART transmit signal/ USB PIN 4...
  • Page 121 Appendices USB Cable Pinouts 1,828.80 mm POWERSCAN D8590 User’s Manual...
  • Page 122: Appendix B Electrical Specifications

    Electrical Specifications RS-232 Cable Pinouts 1,066.80 mm 177.80 mm 165.10 mm POWERSCAN D8590 User’s Manual...
  • Page 123: Appendix C Default/Reset Procedure

    Appendices Appendix C — Default/Reset Procedure If the POWERSCAN D8590 locks up or becomes unresponsive, or if you would like to clear all configuration and programming from the imager, follow the procedure below. Important: The following procedure will clear the buffer, default configuration, and XML programming, including Preamble and Postamble.
  • Page 124: Appendix D Maintenance

    Maintenance Appendix D — Maintenance The POWERSCAN D8590 provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable operation. Cleaning the POWERSCAN D8590 Window The POWERSCAN D8590 has a clear, anti-reflective coated optical window that protects the POWERSCAN D8590 illumination system and optics.
  • Page 125: Appendix E Troubleshooting

    Appendices Appendix E — Troubleshooting Problem: No Data Output. When the trigger is pulled, the unit beeps and then triple-beeps, but does not output data. Error Messages (String Output): None. Possible Cause: POWERSCAN D8590 is not connected (USB or Serial) to the PC. Solution: 1.
  • Page 126 Error Messages (String Output): “License Key Failed” Possible Cause: The POWERSCAN D8590 license has been deleted. Solution: Request license file (2019_(serial number).crb) from Datalogic customer support. Unit serial number and license must match. Once you have received the license file...
  • Page 128: Eugene, Or

    Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 Telephone: (541) 683-5700 May 2013 820057190 (Rev A)

Table of Contents