Indoor Unit Installation
4.
Shaping the refrigerant pipe
•
Form the shape of the refrigerant pipe in accordance with the restric-
tions shown in the illustration.
•
Protect the open end of the pipe against dust and moisture.
Piping pull-out dimensions
: 320
Liquid pipe
These dimensions are for reference. Please adjust them according to
the conditions at the installation site.
CAUTION
Min. allowable length
•
The suggested shortest pipe length is 2.5m, in order to avoid noise from the outdoor unit and vibration.
(Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used.)
•
See the installation manual for the outdoor unit for the maximum pipe length.
•
For multi-connections, see the installation manual for the multi-outdoor unit.
11
Wall
Gas pipe
Bottom edge of the unit
Floor
Left back
piping
Left piping
Centre of the
wall hole
Left bottom
piping
(unit: mm)
Be sure to
place a cap.
Rain
If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.
Refrigerant pipe
105
Right bottom
piping
Wall
Right back
piping
Wall
Right piping
Floor
English