1. Technical Data - Page 3
Weight - Packed - Fire
Weight - Unpacked - Fire
Weight - Packed - Facia
Weight - Unpacked - Facia
Gas Connection
Tap
Burner
Injector - Burner
Injector - Pilot
Pressure Test Point
Spark Gap
Gas Rate on Setting
'HI'
Heat Input on Setting:-
'LO'
'HI'
Heat Output on Setting:-
'LO'
'HI'
Burner Pressure on 'HI' - Cold
Illusion
Stratton
23.90kg (52.7lb).
23.90kg (52.7lb).
18.98kg (41.8lb).
18.98kg (41.8lb).
21.25kg (46.8lb).
17.00kg (37.5lb).
19.29kg (42.5lb).
15.10kg (33.3lb).
¼" Male Flare via Boiler Isolation Valve at Right Hand side of fire.
Combined Tap, Flame Supervision Device and Piezo.
Simplex - Fixed Aeration - Mica Filled Tray.
Marked Bray CAT 28/340
Sit OxyPilot
On Pipework at Left Hand Side of Fire.
3 - 4mm - Pre-set, Non Adjustable.
0.49 m³/h (17.29 ft³/h).
3.8kW ( 12,965Btu/h).
5.4kW ( 18,425Btu/h).
0.96kW ( 3,275Btu/h).
1.5kW ( 5,118Btu/h).
17.3 ± 1 .0mbar (6.9 ± 0.4in w.g.).
Presence
23.90kg (52.7lb).
18.98kg (41.8lb).
8.30kg (18.3lb).
5.30kg (11.6lb).