2.

Removing the Fixing Heat

Discharge Fan

1) Remove the rear cover.
2) Remove the four screws [1], and discon-
nect the connector [2]; then, slide out the
fixing assembly heat discharge fan [3].
Caution:
When mounting the fixing heat dis-
charge fan, be sure that the direction of
air current match the marking indicated
on the fan.
3.
Removing the Scanner Cooling
Fan
1) Open the front door.
2) Remove the inside cover (process unit).
3) Remove the inside upper cover.
4) Remove the two screws [1], and slide out
the scanner cooling fan [2].
Caution:
When mounting the scanner cooling fan,
be sure that the direction of air current
matches the marking indicated on the
fan.