GE Monogram ZV30H Installation Instructions Manual page 9

30” wall-mounted hood
Hide thumbs Also See for Monogram ZV30H:
Table of Contents

Advertisement

Available languages

Available languages

Vent Mode
In vent mode, installation can be done with or with-
out the riser. You must consider 3 1/2" riser height in
determining the hood installation height.
To determine the hood installation height with riser:
X = C - (A + B + R + Y + Z)
Example: X = 96" - (36" + 10 1/2" + 3 1/2" + 15" + 6")
X = 25"
Installation Preparation
Z
Y
R=3 1/2" (Optional)
B=10 1/2"
C=Ceiling
Height
X=24" Min, 36" Max
A
To determine the hood installation height without
riser:
X = C - (A + B + Y + Z)
Example: X = 96" - (36" + 10 1/2" + 24" + 0")
X = 25 1/2"
NOTE: Installation height should be measured from
the cooking surface to the bottom of the hood. The
vent hood must be installed 24" min. and 36" max.
above the cooking surface. The hood installation
height, from the cooking surface to the bottom of the
hood, depends upon ceiling height and other factors
which must be considered .
9
Z=0
Y
B=10 1/2"
C=Ceiling
X=24" Min, 36" Max
A
Height

Advertisement

Table of Contents
loading

This manual is also suitable for:

Monogram zv30hs