4. Adjustments

4-10. [F5] : Camera Adjustment

(shutter adjustment, adjustment for reduced aperture sensitivity, ISO sensitivity adjustment, white balance adjustment, AE
adjustment, offset level adjustment, Shading adjustment)
< Setup for Camera Adjustment>
Finish the calibration of the pattern box before Camera adjustment.
<Step 1>
Select [F5] Camera Adjustment on the [Adjustment Items Select] screen.
--> The [Camera Adjustment Preparation] screen appears.
<Step 2>
Run the adjustment in accordance with the instructions on the screen.
Camera adjustment
< Camera Adjustment Preparations >
(1) Prepare the LB140 filter.
(2) Adjust the color temperature of the pattern box (PTB450)
to 6100+-50K.
(3) Adjust the luminance of the pattern box (PTB450)
to 160+-5cd/m
.
2
(4) Fix the camera on a tripod and set it in front of the
pattern box.
When preparations (1)-(4) are complete,
press the [Enter] key on the PC.
--> Lens is extended when the [Enter] key is pressed.
<Note>
An error will occur during Camera adjustment, and adjustment cannot be completed, unless the pattern box is calibrated
correctly.
--> The [Shutter adjustment (without filter)] screen appears.
52
Maximum 40mm
Maximum 5mm
Maximum 30mm
Centerline
Filter (LB140)
FinePix A400 Service Manual
Pattern box
<Fig. 4-10-1>