Complete Conversion

1. Refer to the "Make Gas Connection" section for properly
connecting the range to the gas supply.
2. Turn the manual shutoff valve in the gas supply line to the
open position.
3. Refer to "Check Operation of Cooktop Burners" in the
"Electronic Ignition System" section for proper burner
ignition, operation and burner flame adjustments.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Checking for proper cooktop and oven burner flames is very
important. The small inner cone should have a very distinct
blue flame ¼" to ½" (0.64 cm to 1.3 cm) long. The outer cone
is not as distinct as the inner cone. LP gas flames have a
slightly yellow tip.
4. Close the oven door and turn the knob to "OFF."
5. Refer to the "Complete Installation" section to complete this
procedure.

Natural Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the "closed" position.
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
2. Unplug range or disconnect power.
14
3. Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
4. Remove the cap from the gas pressure regulator using a flat-
blade screwdriver.
NOTE: Make sure sealing washer remains in the same
position.
5. To convert to Natural gas, unscrew the plastic adjustment
screw by hand, turn it over, and screw it in again.
6. Reinstall the cap.
To Convert Surface Burners
B
1. Remove burner grate, burner caps and burners.
C
A
A. Gas pressure regulator
A
A. Cap
Inlet pressure
Inlet pressure to
to LP gas
Natural gas
C
180º
A. Cap
B. Sealing washer
C. Adjustment screw
A. Burner cap
B. Burner
A
B
A
B