High Level Rpts (cs phone 1: 01001, cs phone 2: 01011,
cs phone 3: 01021)
When this setting is on, the following conditions report to the central sta-
tion:
•
Fire, Police, Auxiliary, and Duress alarms
•
No Activity
•
Receiver Failure (or jam)
•
Tamper conditions, including Zone Tampers and System Tamper (40
incorrect key presses or touchpad supervisory)
•
Entering or exiting Sensor Test mode
•
Phone Test
Note
For UL 1610 & 1635 installations, this feature must be set to on.
Low Level Rpts (cs phone 1: 01002, cs phone 2: 01012,
cs phone 3: 01022)
When this setting is on, the following non-alarm conditions report to the
central station:
•
Force Armed
•
Hardwire Zone Trouble (open or short)
•
Supervisory (wireless devices)
•
Low Battery (wireless devices)
•
Phone Test
•
Other non-alarm related conditions
Note
For UL 1610 & 1635 installations, this feature must be set to on.
Exception Rpts (cs phone 1: 01003, cs phone 2: 01013,
cs phone 3: 01023)
When this setting is on, the panel reports to the central station if the sys-
tem is not armed or disarmed at the specified schedule times.
Open/Close Rpts (cs phone 1: 01004, cs phone 2: 01014,
cs phone 3: 01024)
This setting determines whether opening and closing reports are sent to
the central station. When turned on, the panel sends a closing report when
the system is armed and an opening report when the system is disarmed.
Note
To use this feature, the Opening Reports and Closing Reports settings under
REPORTING
the
menu must be turned on for that partition.
Concord 4 Series Systems
WWW.DIYALARMFORUM.COM
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
To turn High-Level Reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new set-
ting.
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
To turn Low-Level Reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new set-
ting.
Phones-CS 1-3 (Default = off)
To turn Exception Reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Phones-CS 1-3 (Default = off)
To turn Opening/Closing Reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new set-
ting.
HIGH LEVEL RPTS
LOW LEVEL RPTS
EXCEPTION RPTS
OPEN/CLOSE RPTS
32