Setting The Offset Temperature (Tof); Teach-Out / Reset (Res) - eQ-3 MAX! Operating Manual

Wireless wall thermostat
Hide thumbs Also See for MAX!:
Table of Contents

Advertisement

Available languages

Available languages

12° C while the window is opened. Once the MAX! Window
Sensor registers the closing of the window, all components
installed in the room will be reset to the previous mode.
To change the reduced temperature setting proceed as
follows:
• Press the Mode button for more than 3 seconds.
• Select the "AEr" menu item with the (+) and (-) buttons.
• Confirm the setting with the OK button.
• Set the temperature with the (+) and (-) buttons.
• Confirm the setting with the OK button.

17.9 Setting the offset temperature (tOF)

As the temperature is measured on the room control unit the
temperature distribution can vary throughout a room. To
adjust this, a temperature offset of ±3.5°C can be set. If a
nominal temperature of e.g. 20°C is set at the room con-
trol unit but the room presents with only 18°C an offset of
-2.0°C needs to be set.
• Press the Menu button for more than 3 seconds.
• Select the "tOF" menu item with the (+) and (-) buttons.
• Confirm the setting with the OK button.
• Set the offset temperature with the (+) and (-) buttons.
• Confirm the setting with the OK button.

18. Teach-out / Reset (rES)

The initial state of the MAX! Wall Thermostat + can be res-
tored manually, e.g. to teach-in a single room solution to a
MAX! Cube or to re-install an incorrectly operating system.
Restoring the initial state deletes all settings and informa-