Setting The Week Programmes(Pro) - eQ-3 MAX! Operating Manual

Wireless wall thermostat
Hide thumbs Also See for MAX!:
Table of Contents

Advertisement

Available languages

Available languages

Set holiday function (sec. 17.6)
dEC:
Set valve protection function (sec. 17.7)
AEr:
Set "Open window temperature" for automatic
temperature decrease during airing (sec. 17.8)
tOF:
Set temperature offset (sec. 17.9)
rES:
Reset factory settings (sec. 18.)

17.1 Setting the week programmes(Pro)

In the week programme, for each weekday up to 6 heating
phases (13 change settings) can be set separately. The
programming is carried out for the days chosen, whereby
temperature settings have to be set for the entire period
between 00:00 and 23:59.
Press the Mode button for more than 3 seconds.
The display will show "Pro".
Confirm the setting with the OK button. The display
will show "dAy".
Select an individual weekday, all weekdays, the
weekend or the entire week with the (+) and (-) but-
tons (i.e. weekdays).
Confirm setting with the OK button.
Now set the end time of the first time period (i.e.
6:00 am for the period 0:00 – 6:00 am).
Confirm setting with the OK button.
With the (+) and (-) buttons select the chosen tem-
perature for the previously chosen time period (i.e.
17.0°C).
Confirm setting with the OK
button.
46

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents