User Setup Page - GRAUPNER Polaron Operating Instructions Manual

2 channels ac/dc charger
Hide thumbs Also See for Polaron:
Table of Contents

Advertisement

Charge time
Peak voltage
Charge capacity
Internal impedance
of charge battery
NORMAL DATA
1) NORMAL DATA : Real time display of the input/output voltage, temperature, resistance of
battery.
2) CYCLE DATA
: Display of the data according to the cycle number.
- Charge/discharge time: Displays the total time of the charge/discharge process.
- Peak voltage : Display of the max voltage during the charging process.
- Average voltage : Display of the average voltage during the discharging process.
- Charge/discharge capacity : Display of the charge/discharge capacity at completion.
- Internal impedance of the battery : Display of the internal impedance during charging/dis
charging.
3) GRAPH DATA : Display of the graph with the operating voltage, current, and temperature.
The graph reflects the programmed data, entered either automatically or
manually.

◎ USER SETUP PAGE

Tap the USER SET icon on the main page to access to user setup modes (4 modes). The
data can be programmed. The page can be navigated by tapping the DEC/INC buttons.
29
Cycle number
Discharge time
Average voltage
Discharge capacity
Internal impedance
of discharge battery
CYCLE DATA
Tap the USER SET icon to program
the user setup on the main page.
GRAPH DATA
CONFIG MODE 1
DC-IN : DC Input Values from the rear
side (DC 11 ~ 15V). The values shall be
automatically activated after connecting.
The Wattage Setting of the User's SMPS
from the rear side
The Voltage & Current Setting of the User's
SMPS from the rear side
Output Sharing of Ch.1 and Ch.2
(Wattage with percentage)
CONFIG MODE 3
Date & Time : Date, month, year, time setup
Alarm 1 : The first alarm time setup.
Alarm 2 : The second alarm time setup.
Finish Sound : 10 types of sounds are available.
Sound Time : The times available for the charger are
ON, OFF, 5sec, 15sec, and 1min.
Beep : This parameter can be turned on/off to select
either an internal or an external button.
LCD Bright : Backlight brightness can be adjusted
(1-20 steps).
Temp. Scale : The temperature unit can be changed.
Sound Vol. : The sound level can be adjusted. (1-5 steps)
CONFIG MODE 2
CH1 user setup of can be set at CONFIG
MODE 1-4.
Only the Finish sound of CONFIG MODE 1
in CH2 user setup can be set
User Name : Enter user name
Language : Not yet applicable
When not in use, set to OFF
Option
When not in use, set to OFF
AC-IN : AC Input Values from the
rear side. The values shall be auto-
matically activated after connecting.
Low Voltage Error Setting
CONFIG MODE 4
: Not yet applicable
30