Code #40 - Optics Thermistor Error - Ricoh A151 Field Service Manual

Ricoh laser mfp field service manual
Hide thumbs Also See for A151:
Table of Contents

Advertisement

2.10 CODE #40 – OPTICS THERMISTOR ERROR
-Definition-
The optics thermistor is open.
-Possible Cause-
Defective thermistor
Defective main board
CN113 on the main board is not correctly connected.
-Action-
Check the resistance between CN113 pin 1 and pin 2.
∞Ω(Open)
Approx. 8 KΩ
Replace the thermistor
Check the voltage at CN113-2 on the main board.
5 volts
0 volts
Replace the main board
Check the voltage at CN113-1 on the main board.
About 1.8 volts
Replace the thermistor
Replace the main board
FSM
0 volts
6-41
A151/A152

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A202A203A152Ft3013Ft3213Ft3513 ... Show all

Table of Contents