Way Of Referring To The Error History; Optional Code; Relay Cord A Asm. For Standing Machine (Part No. M9701351Aa0) - JUKI LZ-2290 Series Manual Manual

Lz-2290 series direct-drive, computer-controlled, high-speed, 1-needle, lockstitch, zigzag stitching machine
Table of Contents

Advertisement

(3) Way of referring to the error history

You can check the error information occurred in the past.
Error information can be recorded up to 127 cases. (Error information more than 127 cases is overwritten
from older one.)
2
1
17. OPTIONAL COED

(1) Relay cord A asm. for standing machine (Part No. M9701351AA0)

12
1) Wiring diagram of variable pedal PK-70, -71
SPEED VARIABLE RESISTOR
PRESSER LIFTER SWITCH
THREAD TRIMMING SWITCH
HIGH SPEED SWITCH
LOW SPEED SWITCH
• Power source section A sorted by color for each signal appears from the relay cord A asm. for standing
machine. Perform connection of the switches and the speed variable resistor according to the wiring
diagram.
• Use this cord by inserting it into the connector (CN10) of pedal for standing machine in PSC box.
4
3
2
1
Approx. 1.5 mm
11
CN 56
BROWN
5 V
1
2
ORANGE
3
YELLOW
4
S GND
GREEN
5
BLUE
S GND
6
PURPLE
7
GRAY
S GND
8
9
WHITE
S GND
10
LIGHT BLUE
11
PINK
S GND
12
BLACK
1) Pressing switch 1 inside the front cover, turn ON
the power switch.
2) LED displays the latest error information with "peep"
sound. (If there is no error, indication 2 changes to
indicate "Er0".)
3) When switch 3 is pressed, old error information in
the error history can be called. (When the
information reaches the last, an alarm sound
"peeps".
4) When switch 4 is pressed, new error information
in the error history can be called. (An alarm sound
"peeps" at the latest information.)
(Caution) Refer to "16. Error code list" for error
No. and the description.
A
1
VR(1 KΩ)
2
3
To be used with variable
between 1 and 2V
(Acceleration / retardation)
Neutral position :
1V ± 0.05V
(between 3 and 4)
79