13.10 Using the VISCA RS-422 Connector Plug

1
Insert a wire (AWG Nos. 28 to 18) into the desired
wire opening on the VISCA RS-422 connector
plug, and tighten the screw for that wire using a
flathead screwdriver.
2
Insert the VISCA RS-422 connector plug into the
VISCA RS-422 connector.
Flat-head screwdriver
Wire
To remove the connector plug
Grasp both ends of the VISCA RS-422 connector
plug and pull it out as shown in the illustration.
Note
connect both ends to GND.
connectors, the VISCA RS-232C connection is not
available.
RS-422 connection is approximately 1,200 m
(3,937 ft).