Fireplace Specs - Peninsula - Lennox MPD35ST-NM-B Installation Instructions Manual

Merit plus series direct vent gas fireplace heaters
Hide thumbs Also See for MPD35ST-NM-B:
Table of Contents

Advertisement

FIREPLACE SPECIFICATIONS - MPD35PF
SPECIFICATIONS
Natural Gas BTU Input
Propane Gas BTU Input
Co-axial DV Vent Size
NOTES
Annual Fuel Utilization Efficiency
Due to Lennox' ongoing commitment to quality,
all specifications, ratings and dimensions are
subject to change without notice.
Appliance has a factory-installed vent seal cap
(see Figures 16 & 17 on Page 13) in each flue
outlet.
PRODUCT REFERENCE INFORMATION
Cat.
Model
Ship
No.
Weight
H6945
MPD35PF-NM
220 lbs
H6946
MPD35PF-PM
220 lbs
H6947
MPD35PF-NE
220 lbs
EFFICIENCIES
6 % Natural Gas
62 % Prop. Gas
65 % Natural Gas
• AFUE
67 % Propane Gas
22
(559)
Left Side View
Figure 13B
0
Fireplace Framing Specifications
30,000
***This dimension does
28,000
not include the addition
of drywall to the inside of
4-/2" Inner /
framing or clearance for
7-/2" Outer
the Side Vent Seal Cap.
Adjust accordingly for your
installation.
See also, Side Vent Seal Cap
note below.
Ship.
Volumn
35-/4
46W x 26D x
(895)
43H (30 cu.ft.)
46W x 26D x
43H (30 cu.ft.)
46W x 26D x
43H (30 cu.ft.)
Framing Spacers
(top and both sides)
35-/8
(892)
32-5/8
(827)
9
(483)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Notes:
***38-3/4
(984)
5-5/8
(43)
Top View
Vent Seal Cap
Stepped to Accept Drywall
39-3/4 (984)
38-3/8 (899)
Front View
29 /2
(749)
• Inches (millimeters)
• Minimum Framing Stud Size is 2 x 4
• See side views of fireplace below for
gas line inlet location options.
**20-3/4
(527)
Vent Center - Top Vent
10-1/2
with one 90 degree
(267)
elbow
12-1/8
(308)
5-1/8
(130)
Vent Center - Side Vent
with no elbows
12-1/8
(308)
Center of gas line
is 3-/8 inches
(79 mm) up from
floor.
0-7/8 (264)
Vertical Venting Through the Ceiling:
Frame ceiling opening - Use a plumb line
from the ceiling above the appliance to
 (279)
locate center of the vertical run. Cut and/or
frame an opening, 10-1/2" x 10-1/2" (267
mm x 267 mm) inside dimensions, about
this center mark (see Figure 19).
5/8
(6)
3 (76)
Provide additional
space for Side
Vent Seal Cap if
installing against a
solid wall.
Control Switch Wires
Knock-Out
Louvered Control
Gas
Compartment Door
Inlet
3-/8 (79)
6-/4
(59)
Right Side View
**This dimension
based on 5/8" drywall.
For /2" drywall use
2" (533 mm). The
finished dimension
should be 22" (558
mm)
Secure Vent
42-3/4 (086)
Secure Flex
43-/2 (05)
5-1/8
(130)
25-1/2
(648)
 (279)
25-/2
(646)
Junction Box
Knock-Out