Maintenance - Clarke IMAGE 16 I Operator's Manual

Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
EN
OPERATOR'S MAINTENANCE
How To Attach The Auxiliary Floor Tool
To attach the auxiliary floor tool, follow this procedure:
1. Remove the vacuum hose from the recovery tank.
2. Connect the auxiliary floor tool vacuum hose to the
recovery tank and to the auxiliary tool.
3. Connect the solution hose to the machine and to
the tool.
4. Turn the vacuum/accessory switch "I".
5. Operate the optional cleaning tool as normal.
6. When finished cleaning with the optional floor tool,
turn the vacuum/accessory switch "O".
NOTE: Auxiliary floor tools recommended for this machine:
59231A - RM4 (Upholstery)
59230A - RM8 (8" Floor Wand)
59229A - RM12 (12" Floor Wand)
59220A - Plastic Hand Tool 4" (Upholstery)

MAINTENANCE

WARNING: Maintenance and repairs must be done
by authorized personnel only. Keep all
fasteners tight. Use only Clarke parts.
Maintenance performed by someone
other than a Clarke distributor or Clarke
replacement parts could void your war-
ranty.
WARNING: Operating a machine that is not com-
pletely or fully assembled could result in
injury or property damage. Do not oper-
ate this machine until it is completely
assembled. Inspect the machine care-
fully before operating.
NOTE: For maintenance of the optional floor tools, read
the manual supplied with the tools.
After Each Use Of The Machine:
1. To prevent damage to valves and jets, flush one gallon of
clean water through the solution system and the tools.
2. To prevent damage to the bristles, raise the brush off of
the floor by placing the brush height adjustment in the
highest slot.
3. Disconnect the power cord from the outlet.
4. Drain the recovery tank.
5. Rinse out the recovery tank.
6. Use a dry cloth to wipe both tanks and tools, inside and
out.
7. Inspect and clean the screen filter at the rear of the ma-
chine. To remove the filter, turn the filter counterclock-
wise. To install the filter, turn the filter clockwise.
8. To prevent clogged jets due to alkaline buildup, the spray
system should be flushed at least twice a month with
either a white vinegar solution (one quart vinegar to one
gallon of hot water) or an anti-browning solution (mixed as
directed).
9. Remove any lint on the vacuum intake screen. The screen
is located behind the recovery lid and on the end of the
stand pipe. (See Figure 4)
-10-
Figure 4
Clarke
®