bracket (see Figure 14). Secure speed
control to bracket with lock nut by pushing
and turning lock nut with pliers clockwise
until it is tight against bracket.
7. Remove knockout plug from louver panel
by pressing top and bottom retaining clips
(see Figure 11, page 13).
8. Place louver panel, louvers pointing up,
back into framed opening. Align control shaft
with rectangular opening by sliding control
bracket along flange (see Figure 14).
9. Fully seat louver panel into frame open-
ing by gently pressing along ends until
all dimpled retainers have snapped in
place.
10. Place control knob, provided, onto control
shaft (see Figure 14).
11. Check to make sure power cord is com-
pletely clear of blower wheel and there are
no foreign objects in blower wheel. Also,
double check all wire leads and make
sure wire routing is not pinched or in a
precarious position. Correct accordingly.
Caution: never touch blow-
er wheel while in operation.
12. Turn on power to duplex outlet if previ-
ously turned off per warning in column 1,
page 14.
13. Plug in blower power cord to duplex outlet
(see Figure 12, page 14).
Speed
Control
Bracket
Lower
Flange
Control
Knob
Figure 14 - Attaching Speed Control to
Firebox with Panel Louvers
108662-01K
INSTALLATION
Firebox Face
Screw
Hearth
Head and
Pan
Top Hole
Flange
on Bracket
Lock Nut
Control
Shaft
Lower
Louver
www.desatech.com
Continued
14. Turn blower on and check for operation.
Turn blower off by turning knob fully coun-
terclockwise before continuing.
15. Peel off backing paper and stick supplied
wiring diagram decal on firebox bottom
approximately 12" in from of blower (see
Figure 15).
16. Replace all panels and/or brick bottom
panel if previously removed.
Off
110/115
V.A.C.
Black
Green
White
Wiring Diagram
Decal 12" in
Front of Blower
Figure 15 - Location of Wiring Diagram
Decal (Model May Vary From Illustration)
model bk3 Installation
1. Remove knockout plug from louver panel
by pressing top and bottom retaining clips
(see Figure 11, page 13).
2. Place BK3 fan assembly between two leg
stands with fan blades pointing toward
rear of fireplace (see Figure 16).
Screws
BK3 Blower
Figure 16 - Mounting BK3 Blower
Variable
Fan Switch
Fan Switch
(N.O.)
1
Black
2
Blue
On
Red
Blower
Motor
Leg
Stands
(BKT Model
Only)
15