GBC National Service Department
500 Bond Street
Lincolnshire, IL 60069
(800) 790-7787
TO:
SEE DISTRIBUTION
FROM:
NATIONAL SERVICE DEPARTMENT
SUBJECT:
ULTIMA 65 TRIAC TEST AND
ROLLER PRESSURE ADJUSTMENT
TRIAC TESTING:
When testing the Triac it must be tested out of the circuit and at room temperature. Use an Ohm
meter to take the readings between the leads as follows.
.
RED & YELLOW = OPEN
BLUE & YELLOW = OPEN
RED & BLUE
= CLOSED
ROLLER PRESSURE ADJUSTMENT:
When adjusting the roller pressure on the Ultima - 65, keep in mind that
the adjustments must be the same on both sides left to right as follows.
FRONT ROLLERS = the setscrew must be flush with the block.
REAR ROLLERS = leave 4-5 threads showing above the blocks (approx. 6 mm)