Sidewalls/Surrounds; Frame The Fireplace - Heatilator A36R Owner's Manual

Installation and operation
Hide thumbs Also See for A36R:
Table of Contents

Advertisement

C. Sidewalls/Surrounds
Adjacent combustible sidewalls must be located a minimum of 12 in. (305 mm) (may be 24 in) from the fireplace
opening.
Combustible and non-combustible mantel legs, surrounds and stub walls may be constructed per Figure 6.3.
FLUSH
FRONT
10 3/4 in.
[273 mm]
12 in.
[305 mm]
Figure 6.3
Mantel Leg or Wall Projections (Acceptable on both sides of opening)
D. Frame the Fireplace
Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).
Observe all required air space clearances to combustible materials as shown in Figure 6.2.
Framing across the top of fireplace must be above top standoffs.
2 in. (51 mm)
min. air space
clearance
from chimney.
C
B
Figure 6.4
Framing the Fireplace
20
Grid represents 1 in. scale
A
B
A
Heatilator • A36R & A42R • 28376 • Rev AJ • 08/09
4 in.
[102 mm]
BRICK
FRONT
9 3/4 in.
[248 mm]
12 in.
[305 mm]
Header MUST NOT be notched!
D = extra space needed for outside air connection.
If outside air duct has no bend, this dimension may be
reduced as long as minimum clearances are met.
D
Model #
in.
A36
mm
in.
A42
mm
* If interior of chase will be drywalled, add the thickness to
this measurement.
** Adjust header height for a raised floor under fireplace.
A
Fireplace
Opening
Model #
in.
36
A36
mm
914
in.
42
A42
mm
1067
A
B*
C**
43
23
41 1/2
1092
584
1054
49
23
41 1/2
1245
584
1054
B
Outside
Dimensions
42
1067
48
1219
D
8
203
8
203