International comfort products C9MPX Installation Instructions Manual page 9

95+ single stage, category iv, gas furnace
Table of Contents

Advertisement

Figure 4
Dimensions & Clearances
TOP
LEFT SIDE
TRAP (KO) (COUNTERFLOW)
GAS
VENT
AIR INTAKE (KO)
(ALTERNATE)
TRAP (KO)
UPFLOW/HORIZONTAL
THERMOSTAT
1
(57.2)
2
/
4
1
13
/
4
(336.6)
(KO)
5
21
/
8
(549.3)
7
1
/
8
24
(47.6 )
(609.6)
BOTTOM
D
C
1
23
/
8
(587.4)
Cabinet
Unit
Capacity
A
B
1
5
19
/
17
/
8
8
*9MPX060F12
(485.8)
(447.7)
3
1
22
/
21
/
4
4
*9MPX080J12
(577.9)
(539.8)
3
1
22
/
21
/
4
4
*9MPX080J16
(577.9)
(539.8)
1
24
/
23
2
*9MPX100L20
(622.3)
(584.2)
* Denotes Brand
440 01 1051 02
F
AIR INTAKE
VENT
H
G
E
11
6
/
ELECTRICAL
16
1
(177.5)
1
/
4
(318)
1
(27)
1
/
16
11
13
31
4
/
16
(34.9)
(804.9)
(122.2)
(758.8)
3
1
/
8
7
29
/
8
3
28
/
7
4
(177.8)
(730.3)
1
24
/
16
(611.2)
5
17
/
19
16
(439.7)
11
1
/
16
(42.9)
7
4
/
8
(123.8)
Drawing is representative,
but some models may vary
7
3
/
8
(98.4)
ALL DIMENSIONS − in(mm)
1 IN = 25.4 MM
Bottom
Top
C
D
E
F
1
3
3
1
2
/
14
/
4
/
4
/
8
4
8
2
(54)
(374.7)
(111.1)
(114.3)
15
3
3
1
1
/
18
/
4
/
4
/
16
4
8
2
(49.2)
(476.3)
(111.1)
(114.3)
15
3
3
1
1
/
18
/
4
/
4
/
16
4
8
2
(49.2)
(476.3)
(111.1)
(114.3)
7
3
1
/
23
4
/
4
/
16
8
2
(11.1)
(584.2)
(111.1)
(114.3)
Specifications are subject to change without notice.
A
B
FRONT
11
13
/
16
(347.7)
/
16
13
/
16
(503.2)
G
H
1
1
2
/
9
/
2
2
3
1
/
(63.5)
(241.3)
16
(30.2)
5
3
2
/
11
/
8
8
(66.7)
(288.9)
5
3
2
/
11
/
29
8
8
(758.8)
(66.7)
(288.9)
1
1
2
/
12
/
4
4
13
9
/
(57.2)
(311.2)
16
(249.2)
11
33
/
16
(855.7)
KO = KnockOut
MINIMUM CLEARANCES TO COMBUSTIBLE
MATERIALS FOR ALL UNITS − in (mm)
REAR
FRONT (combustion air openings in
furnace and in structure)
Required For Service
ALL SIDES Of SUPPLY PLENUM
SIDES
VENT
TOP OF FURNACE
*
30" (762mm) clearance recommended for furnace removal.
Horizontal position: Line contact is permissible only between
lines formed by intersections of top and two sides of furnace
jacket, and building joists, studs or framing.
NOTE: Evaporator "A" coil drain pan dimensions
may vary from furnace duct opening size. Always
consult evaporator specifications for duct size
requirements.
Furnace is designed for bottom return or side
return.
Return air through back of furnace is NOT allowed.
1
1
/
4
(31.7)
7
2
/
28
8
(73)
5
(109.5)
4
/
(723.9)
16
3
2
/
(60.3 )
8
1
(27)
1
/
16
RIGHT SIDE
GAS (KO)
TRAP (KO)
(COUNTERFLOW)
ELECTRICAL (KO)
AIR INTAKE (KO)
(ALTERNATE)
13
4
/
16
(122.2)
VENT (KO)
TRAP (KO)
1
1
/
UPFLOW/HORIZONTAL
16
7
/
(27)
8
7
3
27
/
16
(177.8)
(690.6)
5
THERMOSTAT
21
/
8
(549.3)
5
17
/
16
(439.7)
11
1
/
16
(42.9)
21
7
4
/
8
(549.3)
(123.8)
24
(609.6)
0
3" (76.2)
*
24" (609.6)
1" (25.4)
0
0
1" (25.4)
1
/
2
3
(19.1)
/
1
18
/
4
2
(469.9)
TYPE
40
(1016)
1
2
/
4
(57.2)
1
13
/
4
(336.6)
(KO)
5
/
8
7
1
/
8
(47.6)
25−23−36b
9