4-5) Load Operation Check Function; 4-6) Restoration Function For Power Outage; 4-7) Set Point Shift Function - Samsung RS265 LAWP Service Manual

Side by side refrigerator
Table of Contents

Advertisement

4. ALIGNMENT AND ADJUSTMENTS

4-5) Load Operation Check Function

1) In the normal operation, press Power Freeze and Power Cool buttons simultaneously for 6 seconds, then the display
panel will blink for 2 seconds.
2) Press Fridge Temp. button
3) Each illuminating LED segment stands for the component which has an ouput signal from the control board.
4) This mode will terminate automatically after 30 seconds.
Table of Load Mode Check List
NO
Contents
REFRIGERATOR FAN High or AC
motor operation
REFRIGERATOR FAN Low
REFRIGERATOR DEFROST heater
Start mode
Overload mode
Low-temperature mode
Exhibition mode
COMPRESSOR
FREEZER FAN High
FREEZER FAN Low
FREEZER DEFROST Heater
CONDENSER FAN High
CONDENSER FAN Low
Dispenser-Heater
Damper
-
Normal condition
For the REFRIGERATOR FAN, only one rpm is applied for the current models, so that
REFRIGERATOR FAN operation only.
The FREEZER FAN and CONDENSER FAN are operated to High/Low rpm automatically according to the
operational condition.
and
only explain the system operation state according to the ambient condition

4-6) Restoration Function for Power Outage

1) When the freezer temperature is lower than 41 , all functions on the display panel will be restored.
2) When the freezer temperature is higher than 41 , all functions will be initialized.
(-4 for the freezer, 38

4-7) Set Point Shift Function

Press Freezer Temp. and Power Cool buttons simultaneously for 12 seconds to get into this mode.
In this mode, only the display LEDs for temperature will be ON.
to get into this check mode with an audible tone.
for the refrigerator, and Cubed for the Ice Type)
31
and
show

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs267 labpRs267 lashRs269 larsRs265 labp

Table of Contents