4. TROUBLEShOOTING
4-5) Load Operation Check Function
1) in the normal operation, press lighting and energy Saver(Vacation) buttons simultaneously
for 6 seconds, then the display panel will blink for 2 seconds.
2) Press Fridge temp. button ⓐ to get into this check mode with an audible tone.
3) each illuminating leD segment stands for the component which has an ouput signal from
the control board.
4) this mode will terminate automatically after 30 seconds.
Press both buttons simultaneously for 6 seconds,
all leD lightings will be turned off, at this time
press button
ⓐ .
※ the FReezeR Fan and conDenSeR Fan are operated to high/low rpm automatically according to the
operational condition.
※ ② and ③ only explain the system operation state according to the ambient condition
4-6) Restoration Function for Power Outage
1) When the freezer temperature is lower than 41℉(5℃), all on the display panel will be
restored.
2) When the freezer temperature is higher than 41℉(5℃), all functions will be initialized.
(level 4(-20℃) for the freezer, (level 4(3℃) for the refrigerator, and cubed for the ice type
energy Saver on corresponding models'
✽ Self-diagnostics check list
no
error
Damper
①
overload mode
②
low-temperature mode
③
ⓐ
exhibition mode
◀
④
coMPReSSoR
⑤
FReezeR Fan high
⑥
⑦
FReezeR Fan low
FReezeR DeFRoSt
⑧
heater
conDenSeR Fan high
⑨
⑩
conDenSeR Fan low
⑪
Dispenser-heater
-
normal condition
38
leD Display
Right - ① leD on
Right - ⑤ leD on
Right - ⑥ leD on
Right - ⑦ leD on
left - ① leD on
left - ② leD on
left - ③ leD on
left - ④ leD on
left - ⑤ leD on
left - ⑥ leD on
left - ⑦ leD on
Right - ⑤,⑥ leD on
leD all off