Operation Function
3) When you select Power Freeze and Power Cool together
Each function works at the same time. The COMP and F-FAN run continuously and the R-FAN runs until 25℉
in the refrigerator.
4) Initial Power-On
4-1) When the freezer and the refrigerator temperatures are higher than 14℉ and 50℉, respectively, if Power Freeze is
selected, then the R-FAN will be off. If Power Cool is selected, then the F-FAN will be off.
4-2) When both functions are selected, there is no benefit of fast cooling for each compartment.

9-4) Sound Function

1) Sound function
1-1) To make sure a command input, whenever a button is pressed, a "ding-dong" sounds.
1-2) When two or more buttons are pressed simultaneously or if a wrong button is pressed, there is no
sound.
2) Door Open Alarm
2-1) When the doors remain open for 2 minutes, there are 10 times beeps.
2-2) If the doors continue to remain open more than 2 minutes, the additional 10 beeps interval will change to
1 minute.
2-3) The beeps will cease immediately when the doors are closed.

9-5) Defrost Function

1) A defrost is determined based on the accumulated compressor on-time.
2) When the power is engaged for the first time, the defrost cycle for the freezer and the refrigerator will
begin after 4 hours of the accumulated compressor on-time.
3) A defrost interval depends on the ambient temperature, the number of door openings, and the door open
time.
4) The defrost cycle is composed of a pre-cool process (F-Fan and COMP) for 30 minutes, a heating
process, and a resting for 8-12 minutes to drain.
5) A minimum interval is 6 hours and a maximum is 11 hours for the refrigerator, and 12 hours and 22 hours
for the freezer, respectively.
6) When the system runs only for the refrigerator (R-Fan and COMP) and if the refrigerator can not reach the
set temperature within 2 hours, an R-defrost process will begin.
7) After the 6) process, when the compressor on-time reaches 4 hours, R-,F-defrost will begin
simultaneously.
8) If a defrost cycle ocurs during Power Freeze operation, the defrost cycle will begin after the completion of
Power Freeze operation.