PRODUCT DESIGN
Sizing Between Second or Second Stage Regulator & Appliance*
Maximum Propane Capacities listed are based on 1/2" W.C. pressure drop at 11" W.C. setting.
Capacities in 1,000 BTU/hour.
Pipe or
Tubing
Tubing Size, O.D. Type L
Length
Feet
3/8"
1/2"
5/8"
3/4"
10
39
92
199
20
26
62
131
30
21
50
107
40
19
41
90
50
18
37
79
60
16
35
72
1,211
80
13
29
62
100
11
26
55
125
10
24
48
150
9
21
43
200
8
19
39
250
8
17
36
*Data in accordance with NFPA pamphlet No. 54
Propane Gas Piping Charts
When installing a propane storage tank, the contractor must
consider proper tank sizing, safety, efficiency, ground char-
acteristics and aesthetics. For a residential customer, the
size may range from 100-1,000 gallons, depending on
household use. Typically, a 500 gallon tank is ample for an
average four-bedroom home. However, it is best to consult
your local propane supplier to ensure the proper sizing for
propane storage requirements. Determining the correct tank
size for each household is a function of demand, economy,
efficiency and convenience. It is a process that requires
cooperation between the propane supplier and customer.
ELECTRICAL CONNECTIONS
T
O AVOID THE RISK OF ELECTRICAL SHOCK, WIRING TO THE UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
HIGH VOLTAGE
D
ALL
ISCONNECT
POWER BEFORE SERVICING OR
M
INSTALLING THIS UNIT.
ULTIPLE POWER SOURCES MAY
F
BE PRESENT.
AILURE TO DO SO MAY CAUSE PROPERTY
DAMAGE, PERSONAL INJURY OR DEATH.
L
ABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
W
IRING ERRORS CAN COUSE IMPROPER AND DANGEROUS OPERATION.
V
ERIFY PROPER OPERATION AFTER SERVICING.
WIRING HARNESS
The wiring harness is an integral part of this furnace. Field
alteration to comply with electrical codes should not be re-
quired. Wires are color coded for identification purposes.
Nominal Pipe Size
Schedule 40
7/8"
1/2"
3/4"
1"
1-1/4" 1-1/2"
329
501
275
567
1,071 2,205
216
346
189
393
732
1,496
181
277
152
315
590
1,212
145
233
129
267
504
1,039
131
198
114
237
448
913
187
103
217
409
834
104
155
89
185
346
724
90
138
78
162
307
630
81
122
69
146
275
567
72
109
63
132
252
511
66
100
54
112
209
439
60
93
48
100
185
390
WARNING
WARNING
CAUTION
Refer to the wiring diagram for wire routings. If any of the
original wire as supplied with the furnace must be replaced,
it must be replaced with wiring material having a tempera-
ture rating of at least 105° C. Any replacement wiring
must be copper conductor.
115 VOLT LINE CONNECTIONS
3,307
Before proceeding with electrical connections, ensure that
2,299
1,858
the supply voltage, frequency, and phase correspond to
1,559
that specified on the unit rating plate. Power supply to the
1,417
furnace must be N.E.C. Class 1, and must comply with all
1,275
1,066
applicable codes. The furnace must be electrically
976
grounded in accordance with local codes or, in their ab-
866
787
sence, with the latest edition of The National Electric Code,
665
ANSI NFPA 70 and/or The Canadian Electric Code CSA
590
C22.1.
Use a separate fused branch electrical circuit containing
properly sized wire, and fuse or circuit breaker. The fuse
or circuit breaker must be sized in accordance with the
maximum overcurrent protection specified on the unit rat-
ing plate. An electrical disconnect must be provided at
the furnace location.
NOTE: Line polarity must be observed when making field
connections.
Connect hot, neutral, and ground wires as shown in the
wiring diagram located on the unit's blower door. Line po-
larity must be observed when making field connections.
Line voltage connections can be made through either the
right or left side panel.
E
DGES OF SHEET METAL HOLES MAY BE SHARP.
WHEN REMOVING HOLE PLUGS.
NOTE: Wire routing must not interfere with circulator
blower operation, filter removal, or routine maintenance.
T
O AVOID THE RISK OF ELECTRICAL SHOCK, INJURY, OR DEATH, THE
FURNACE MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL
CODES OR, IN THEIR ABSENCE, WITH THE LATEST EDITION OF THE
N
E
ATIONAL
LECTRIC
CAUTION
U
SE GLOVES A PRECAUTION
WARNING
C
ODE.
33