ESIE12-06
FUQ (4-way Ceiling)
Model
Cooling capacity
Heating capacity
Power input
SEER
SCOP
EER
COP
Energy label
Annual energy consumption
Notes:
1.
2.
3.
4.
5.
6.
Model
Cooling capacity
Heating capacity
Power input
SEER
SCOP
EER
COP
Energy label
Annual energy consumption
Notes:
1.
2.
3.
4.
5.
6.
FVQ (Floor Standing)
Indoor unit
Model
Outdoor unit
Cooling capacity
Heating capacity
Cooling (Nom.)
Power input
Heating (Nom.)
SEER
SCOP
EER
COP
Cooling
Energy label
Heating
Annual energy consumption
Notes:
1.
2.
3.
4.
5.
6.
Specifications
Indoor unit
Outdoor unit
Cooling (Nom.)
Heating (Nom.)
Cooling
Heating
Energy label: scale from A (most efficient) to G (less efficient)
Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
Annual energy consumption is according to Energy labeling directive 2002/31/EC
SEER and SCOP are according to EN 14825
Indoor unit
Outdoor unit
Cooling (Nom.)
Heating (Nom.)
Cooling
Heating
Energy label: scale from A (most efficient) to G (less efficient)
Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
Annual energy consumption is according to Energy labeling directive 2002/31/EC
SEER and SCOP are according to EN 14825
FVQ71CVEB
RZQG71L7V/Y1B
(3)
kW
6.8
(4)
kW
7.5
kW
2.02
kW
2.06
(6)
5.16
(6)
3.81
3.37
3.64
kWh
1,010
Energy label: scale from A (most efficient) to G (less efficient)
Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
Annual energy consumption is according to Energy labeling directive 2002/31/EC
SEER and SCOP are according to EN 14825
FUQ71BWV1B
RZQG71L7V1B
(3)
kW
6.8
(4)
kW
7.5
kW
1.68
kW
1.84
(6)
5.25
(6)
3.89
4.05
4.08
A
kWh
840
FUQ71BVV1B
RZQG71L7V1B
(3)
kW
6.8
(4)
kW
7.5
kW
1.68
kW
1.84
(6)
5.65
(6)
3.95
4.05
4.08
A
kWh
840
FVQ100CVEB
RZQG100L7V/Y1B
(3)
9.5
(4)
10.8
2.49
2.61
(6)
5.59
(6)
3.80
3.81
4.14
A
A
1,245
Specifications
FUQ100BWV1B
FUQ125BWV1B
RZQG100L7V/Y1B
RZQG125L7V/Y1B
(3)
9.5
(4)
10.8
2.46
2.73
(6)
4.67
(6)
4.02
3.86
3.95
A
1,230
FUQ100BVV1B
FUQ125BVV1B
RZQG100L7V1B
RZQG125L7V1B
(3)
9.5
(4)
10.8
2.46
2.73
(6)
4.67
(6)
4.02
3.86
3.95
A
1,230
FVQ125CVEB
FVQ140CVEB
RZQG125L7V/Y1B
RZQG140L7V/Y1B
(3)
12.0
13.4
(4)
13.5
15.5
3.74
3.65
(6)
4.77
(6)
3.85
3.21
3.70
1,870
(3)
12.0
(4)
13.5
3.54
3.95
(6)
4.41
(6)
4.09
3.39
3.42
B
1,770
(3)
12.0
(4)
13.5
3.54
3.95
(6)
4.41
(6)
4.09
3.39
3.42
B
1,770
(3)
(4)
4.17
4.30
3.21
3.61
2,085
11