Y
-
SUS P101 to Control P111 Plug Voltage Checks
Y
-
SUS P101 to Control P111 Plug Voltage Checks
"Y-SUS" P101 CONNECTOR to "Control" P111
Pin
Label
1
15V
3
15V
5
5V
7
5V
9
CTRL_OE
11
Gnd (Y Enable)
13
Gnd
15
Delta VY Det
17
Set On
19
Det Level Sel
21
Slope Rate Sel
23
ER DN
25
SUS DN
27
ER UP
29
YSUS UP
Diode Mode Readings taken with all connectors Disconnected. DVM in Diode Mode.
Diode
Run
Mode
17.04V
1.37V
17.04V
1.37V
5V
2V
5V
2V
0.1V
1.3
0V
1.78V
Gnd
Gnd
1.99V
0.9V
0.5V
0.9V
1.29V
0.9V
0.17V
0.9V
0.114V
0.9V
2.6V
0.9V
0.14V
0.9V
0.11V
0.9V
There are No Stand By Voltages on this Connector
TIP: For Voltage readings,
Check Odd pins on Y-SUS board
Check Even pins on Control board
Pin
Label
2
15V
4
5V
6
5V
8
Gnd
10
OE
12
Gnd
14
OC2
16
Data
18
OC1
20
STB
22
CLK
24
SET UP
26
Ramp Slope OPT 1
28
Blocking
30
Gnd