Y
-
SUS BOARD SECTION
Y
-
SUS BOARD SECTION
Y-SUS Board develops the V-Scan drive signal to the Y-Drive boards.
This Section of the Presentation will cover troubleshooting the Y-SUS Board for the Single
Scan Plasma. Upon completion of the Section the technician will have a better
understanding of the operation of the circuit and will be able to locate voltage and
Diode mode test points needed for troubleshooting and alignments.
Adjustments
DC Voltage and Waveform Checks
Diode Mode Measurements
Operating
Voltages
Operating
Voltages
SMPS Supplied
Y-SUS Developed
Floating Ground
(Overview)
(Overview)
VA
VA supplies the Panel Vertical Electrodes (Routed to the Left X-Board)
VS
VS Supplies the Panel Horizontal Electrodes (Also routed to the Z-SUS board)
M5V
5V Supplies Bias to Y-SUS (Then Routed to the Control board and Z-SUS board)
-VY VR502
-VY Sets the Negative excursion of the Y-SUS Drive Waveform
VSC VR501
VSC Set the amplitude of the complex waveform.
V SET UP VR601
SET UP sets amplitude of the Top Ramp of the Drive Waveform
V SET DN VR602
SET DOWN sets the Pitch of the Bottom Ramp of the Drive Waveform
15V
To the Control Board then routed to the Z-SUS board
FG 5V
Used on the Y-Drive boards (Measured from Floating Gnd)
FG 15V
Used in the Development of the V-Scan signal (Measured from Floating Gnd)
43