50PQ30 SERVICE TIP SECTION
50PQ30 SERVICE TIP SECTION
Floating Ground checks must be made from Floating Ground. Use any pin on P204, P203, P205 or P208.
SYMPTOM:
The panel indicates a brief flash during start up, then "No Picture" symptom.
CHECKS:
1. Z-SUS does not produce a correct signal. (All voltages check normal except 17V).
2. Y-SUS does not produce a correct signal. (No negative portion).
3. On Y-SUS: 17V starts off at 17V then very quickly drops to 5V.
4. Floating Ground 5V and 15V are not produced. (See pages 60~61 for more details).
5. Removing all connectors on the Z-SUS board (Except the panel connectors) does
not change test results.
6. Removing Y-Drive boards cause all voltages to return to normal.
Including the Y-Drive signal checked on the right side of C213.
7. Reconnecting all connectors on the Z-SUS board shows it is not creating a
correct waveform. Just spikes. (17V now stays up).
8. Using the Diode Checks for the Y-Drive boards do not indicate a problem.
(See pages 67, 70, 71 and 74 for more details).
FIX:
Replacing the Z-SUS board fixed the problems.
TIP: