7.6.3

Control Center Questions

How do I set the control center's address?
On the control center's printed circuit board, turn the rotary switch to the desired position (1 to 4). Each control center
must have a unique address.
The control center does not initialize. All I see is a flashing amber circle.
Ensure that the rotary address switch on the control center's printed circuit board is properly set and not halfway between
two numbers. Also, ensure that each control center has a unique address from 1 to 4.
The control center does not recognize any of my tokens.
If you have more than one control center, they are mounted too close to each other.
Ensure that there is at least 1.2 m (4 ft) between each control center.
Ensure that you do not run two or more sets of control center wiring together. Also, ensure that you do not coil extra
control center wiring inside of the control panel's enclosure.
If you have more than one token on a keychain, separate the tokens. Tokens that are too close to one another interfere
with control center operation.
The control center beeps when I present a token, but nothing else happens.
Your token is unassigned. If you are the master user, enter the master user passcode, select the User Menu, and assign a
token to yourself. For all other users with this problem, the master user must enter the User Menu and assign a token to
the appropriate user(s).
7.6.4

Passcode Questions

What are the default installer and master user passcodes?
Default installer passcode: 5432 when passcode length = four digits; 543211 when passcode length = six digits
Default master passcode: 1234 when passcode length = four digits; 123455 when passcode length = six digits
I cannot enter the Installer Menu using the installer passcode.
Expert Programming Item Number 142, Restrict Installer Passcode, is enabled. The master user must first present his or
her token, or enter his or her passcode, before you enter the installer passcode. The Installer Passcode is enabled until a
user turns the system on.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Easy Series (ICP-EZM2) | Installer Guide | 7.0 Reference Materials
67