Hanging On The Wall Lengthwise - Pioneer PDP-425CMX Technical Manual

For pioneer plasma display monitor when used with video cards (expansion solutions cards)
Hide thumbs Also See for PDP-425CMX:
Table of Contents

Advertisement

Special Installation (Hanging on the wall lengthwise)

3.4.6 Hanging on the wall lengthwise

Carefully read the following imformation before attempting to mount the unit on the wall. Observe the various limitations
specified below.
Be sure to mount the unit so that twisting, bending, or any other deformation does not exceed 4 mm.
Attach so that the fan is on the left
side when viewed from the rear.
D
A
Operating Temperature Restrictions
Distance from wall (A)
50 mm or more
*1
For this installation, set the 'FAN CONTROL' to 'MAX' as shown in "5.4.3 Adjustment and Setting in the Integrator
Mode 14) Cooling Fan Control Setting" (pg. 172).
*2
When INPUT2 has been selected, use input compatible signal up to 1280x1024 (60 Hz) at ambient temperature
condition of 0 °C to 35 °C.
36
Shaded areas
: Thermometer (temperature measurement point)
21.6
610
10
(*1, *2)
B
100 mm or more
50 mm or more
indicate attachment points for mounting hardware.
Avoid blocking or
covering this area
on the upper and
lower sides.
93.4
D
C
D
50 mm or more
10
Ambient temperature
0 °C to 35 °C