Dew Sensor - Panasonic Digital Palmcorder PalmSight PV-DV100 Service Manual

Digital video camcorder
Hide thumbs Also See for Digital Palmcorder PalmSight PV-DV100:
Table of Contents

Advertisement

DEW Sensor

CAUTION:
DO NOT touch
the element part
7 DEW Sensor
Sheet
3 mm ~ 5 mm
DEW Sensor Leads
Portion A
Disassembly Notes:
1. DO NOT touch the element part on DEW Sensor when
removing.
2. When removing the DEW Sensor, remove the DEW Sensor
using a screwdriver etc. as shown.
View A
0 mm ~ 2 mm
4 mm ~ 7 mm
Fig. DM7
2-25
Screwdriver
Unsolder
Reassembly Notes:
1. Installation of DEW Sensor
1) Put the DEW Sensor on chassis with adhesive securely,
and then place the sheet as shown.
2) Shape the DEW Sensor Leads while avoiding Porion A,
and then solder it under 320 ºC within 3 Seconds as
shown.
DEW Sensor
chassis
View A
Unsolder