Toshiba e-studio477s User's Manual And Troubleshooting Manual page 11

Multifunctional digital systems
Hide thumbs Also See for e-studio477s:
Table of Contents

Advertisement

Note
• If the inner finisher is installed, be sure to remove any
output paper on it before opening the top cover.
4
Remove the print cartridge and place it on a
flat surface.
Print cartridge
5
Cover the print cartridge with paper so that
it will not be exposed to light.
6
Remove the jammed paper remaining
inside of the unit.
7
Hold the fuser unit handle and lift the fuser
unit out of the machine.
Caution
Possible to get burned.
The fuser unit is extremely hot. Do not touch it.
Fuser unit handle
8
Tilt the release levers on the fuser unit
forward, and be sure to pull out the jammed
paper forward gently.
9
Hold the fuser unit handle and return the
fuser unit into its original position.
Fuser unit handle
10
Return the print cartridge into the machine
carefully.
- 11 -
When a Paper Jam Occurs
Release lever
1
2
3
4
5
6
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents