Schematic Diagram; Schematic Diagram Notes - Panasonic TH-37LRT12U Service Manual

High definition hospitality lcd display
Hide thumbs Also See for TH-37LRT12U:
Table of Contents

Advertisement

12 Schematic Diagram

12.1. Schematic Diagram Notes

Notes:
1. Resistor
Unit of resistance is OHM [Ω] (K=1,000, M=1,000,000)
2. Capacitor
Unit of capacitance is μF, unless otherwise noted.
3. Coil
Unit of inductance is H, unless otherwise noted.
: Test Point position
/ S GND: Chassis Earth (Cold)
P GND: Line Earth (Hot)
4. Voltage Measurement
Voltage is measured by a DC voltmeter.
Conditions of the measurement are the following:
Power Source ....................... AC110-127V, 50/60Hz /
Receiving Signal ................... Colour Bar signal (RF)
All customer's control ........... Maximum positions
5. This schematic diagram is the latest at the time of printing
and subject to change without notice.
Remarks:
1. The Power Circuit contains a circuit area which uses a
separate power supply or you may be shocked.
The circuit defined by HOT and COLD indications in the
schematic diagram. Take the following precautions.
All circuits, except the Power Circuit, are cold.
Precautions:
a. Do not touch the hot part or the hot and cold parts at
the same time or you may be shocked.
b. Do not short-circuit the hot and cold circuits or a fuse
may blow and parts may break.
c. Do not connect an instrument, such as an oscilloscope,
to the hot and cold circuits simultaneously or a fuse
may blow.
d. Make sure to disconnect the power plug before
removing the chassis.
220-240V, 50/60Hz
39
TH-32LRT12U-A * TH-37LRT12U/M/A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents