Error Codes - Mitsubishi Electric WD-57831 Service Manual

Dlp projection hdtv v34 chassis
Hide thumbs Also See for WD-57831:
Table of Contents

Advertisement

4. Error Codes

The Error Code designations indicating malfunction, or no malfunction, are listed in the Table below.
Code
No Error found
12
Lamp cover is open.
32
Lamp turns Off while the TV is playing.
(1)
(Lamp failure)
34
(Lamp Enable signal from engine is lost)
DM fan failed. (73" only)
35
Lamp ballast fan failed.
36
Engine (DLP) fan failed.
37
Lamp temperature abnormally high.
38
DMD temperature abnormally high.
39
Lamp fan failed.
42
Check for disconnected DVI cable between PWB-DM and Engine.
44
DT connector (DMD Temperature sensor) disconnected. (73" only)
46
Temperature of DM is too high.
47
Engine power supply short is detected.
48
Ballast communication problem (ballast to chassis)
(2)
57
Signal Short is detected
58
DM short is detected
59
(3)
No LAMP-EN output from the engine to the ballast
61
Lamp did not turn on at P-ON sequence
(4)
(No Lamp inserted)
66
(Disconnected cable between ballast and lamp)
(Lamp-Enable goes to DM but not to Ballast)
(1)
Code 34
- Lamp Enable is generated to activate the Lamp
(2)
Code 57
- Lamp Enable is generated during P-ON sequence, but no Lamplit signal is received from the Ballast.
(3)
Code 61
- No Lamp Enable is received at the DM and Ballast.
(4)
Code 66
- Lamp enable is received at the DM but not at the Ballast.
MODEL: WD-57831 / WD-65831 / WD-73831
ERROR CODES
Description
Page 26

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wd-65831Wd-73831

Table of Contents