Toshiba PORTEGE M300 Maintenance Manual page 152

Personal computer
Hide thumbs Also See for PORTEGE M300:
Table of Contents

Advertisement

3.19 Hard Disk Test Detail Status
Bit
Name
7
BBK
(Bad block mark)
6
UNC
(Uncorrectable)
5
——
4
IDN
(Identification)
3
——
2
ABT
(Abort)
1
TK0
(Track 0)
0
——
3-40
Table 3-4 Error register contents
"0" ... Not used
"1" ... A bad block mark is detected.
"0" ... There is no uncorrectable data error.
"1" ... Uncorrectable data error has been detected.
Not used
"0" ... Not used
"1" ... There is no ID field in the requested sector.
Not used
"0" ... Not used
"1" ... Illegal command error or command abort.
"0" ... The hard disk found track 0 during a recalibrate
command.
"1" ... The hard disk could not find track 0 during a recalibrate
command.
Not used
PORTEGE M300 Maintenance Manual (960-504)
3 Tests and Diagnostics
Description

Hide quick links:

Advertisement

Table of Contents
loading