MAINTENANCE menu
Page title &
No.
purpose
<OTHERS 1>
M12
Set various
[M08]
subsidiary
(U22 or
functions
U23
when the
optional
HKSR-
9002 is
installed)
Item
Default
SD-BAR
SMPTE
AUDIO SG
ON, OFF
IMAGE
OFF
INVERT
IRIS CLOSE
OFF
SDI REMOTE OFF
SMEAR
OFF
REDUCER
Settings
Remarks
SMPTE, EIA,
Select the color bar
FULL (EBU), 95%,
format for SD output
NTSC100%
EBU, PAL100%: With
(PAL100%)
1.000 formats
OFF
Turn the 1 KHz sine
wave test signal on or
off (when the color bar
selected with HD-
BAR(VF/MON) is
displayed)
ON, OFF
Turn the image-
inversion function on
or off (ON to turn the
camera picture upside-
down)
ON, OFF
ON, OFF
Turn on or off the
function which enables
synchronized recording
of this unit and the
SRW-1/SRPC-1
connected to the SDI
MON1 connector, HD
SDI MON2 connector
or HD SDI OUT A/B
connectors (when the
optional HKSR-9001 is
installed) by feeding
the SRW-1/SRPC-1
with recording trigger
OFF, LOW, HIGH
To set the smear
compensation
function.For
compensation, select
the compensation level,
LOW or HIGH. When
the camera is turned
off, the setting returns
to OFF.
Note
While smear
compensation is
effective for still
pictures, it may
emphasize a smear
with a moving subject.
Be sure to use this
function as appropriate
for the subjects.